Home > Products > Electrical Wire Cable > USE-2 Solar Wire 600V Cable Bare Copper

USE-2 Solar Wire 600V Cable Bare Copper

    Payment Type: L/C,T/T,Paypal,Western Union
    Incoterm: FOB,CFR,CIF,FCA,CPT
    Min. Order: 1000 Meter
Basic Info

Model No.RHW

BrandHUAYUAN YONGTONG

TypeInsulated

Conductor TypeStranded

ApplicationHeating

Conductor MaterialCopper

Sheath MaterialPVC

Insulation MaterialPVC

Material ShapeRound Wire

Range of ApplicationCold-Resistant

CertificationISO9001

BrandHUAYUAN YONGTONG

Additional Info

PackagingDrum

Productivity1000km/M

TransportationOcean,Land,Air

Place of OriginBeijing,China

Supply Ability1000km/M

CertificateCE,CCC,ISO

HS Code8544601200

PortTianjin Port,Shanghai Port,Qingdao Port

Payment TypeL/C,T/T,Paypal,Western Union

IncotermFOB,CFR,CIF,FCA,CPT

Product Description

 USE-2 Solar Wire 600V Cable Bare Copper

1.Application

Type RHH or RHW-2 or USE-2 conductors are for use in conduit or cable tray as specified in the NEC(R). When used as Type USE-2 conductor is suitable for use as underground service entrance cable for direct burial at conductor temperatures not to exceed 90°C. When used as RHH or RHW-2, conductor temperatures shall not exceed 90°C in wet or dry locations. Voltage rating for RHH or RHW-2 or USE-2 conductors is 600V.


2.Compliances

  • UL 44 - Thermoset-Insulated Wires and Cables
  • UL 1581 - UL Flame Exposure Test (VW-1)
  • UL 854 - Service Entrance Cables
  • UL 1685 - UL Flame Exposure Test
  • ICEA S-95-658 (NEMA WC70)
  • IEEE 1202/FT4 - Flame Test (4/0 and Larger) of Cables for Use in Cable Tray in Industrial and Commercial Occupancies (70,000 Btu/hr)
  • ICEA S-95-658 (NEMA WC 70) construction requirements

3.Construction

RHH cable



4.Parameters

Conductor Stranded bare annealed soft copper
Insulation Flame-retardant, abrasion, moisture and heat resistant Cross-Linked Polyethylene (FRXLPE)
Color Upon request, black is preferable

AWG or kcmil Strand Conductor Diameter Nominal insulation Thickness Nominal Overall Diameter Copper Weight Cable Weight
Inch/mm Inch/mm Inch/mm Lbs/kft kg/km Lbs/kft kg/km
14 7 0.07 1.78 0.045 1.14 0.17 4.32 13 19 24 36
12 7 0.09 2.29 0.045 1.14 0.19 4.83 20 30 33 49
10 7 0.12 3.05 0.045 1.14 0.21 5.33 32 48 48 71
8 7 0.15 3.81 0.060 1.52 0.27 6.86 50 75 78 116
6 7 0.18 4.57 0.060 1.52 0.31 7.87 81 121 114 170
4 7 0.23 5.84 0.060 1.52 0.36 9.14 129 192 169 252
2 7 0.29 7.37 0.060 1.52 0.42 10.67 205 305 254 378
1/0 19 0.37 9.40 0.080 2.03 0.53 13.46 326 485 403 600
2/0 19 0.41 10.41 0.080 2.03 0.58 14.73 411 612 501 746
4/0 19 0.52 13.21 0.080 2.03 0.69 17.53 653 972 760 1131
250 37 0.56 14.22 0.095 2.41 0.77 19.56 772 1149 906 1349
350 37 0.67 17.02 0.095 2.41 0.87 22.10 1081 1609 1237 1841
500 37 0.80 20.32 0.095 2.41 1.00 25.40 1542 2295 1730 2575
750 61 0.98 24.89 0.110 2.79 1.22 30.99 2316 3447 2576 3834
1000 61 1.13 28.70 0.110 2.79 1.37 34.80 3086 4593 3405 5068


5. The products picture

flexible cable


LHW cable

Wire insulation Types (1)

Technical Parameter of wire cable electrical

SIZE AWG CROSS SECTION STRANDING number of INSULATION  EXTERNAL  TOTAL WEIGHT
MCM   AL mm2  wire x diametre mm THICKNESS 
mm
DIAMETER 
mm
 KG/KM
20 0.52 1×0.813 0.76 2.33 9.81
18 0.82 1×1.02 0.76 2.54 13.16
16 1.31 1×1.29 0.76 2.81 18.1
14 2.08 1×1.63 0.76 3.15 26.1
12 3.31 1×2.05 0.76 3.57 38.3
10 5.26 1×2.59 0.76 4.11 57.4
8 8.34 1×3.26 1.14 5.54 95.2
14 2.08 7×0.62 0.76 3.38 27.8
12 3.31 7×0.78 0.76 3.86 40.1
10 5.26 7×0.98 0.76 4.46 59.9
8 8.37 7×1.23 1.14 5.97 105.2
6 13.3 7×1.55 1.52 7.69 170.4
4 21.15 7×1.96 1.52 8.92 255.5
2 33.62 7×2.47 1.52 10.45 388.9
1 42.36 7×2.78 2.03 12.4 482.9
1/0 53.49 19×1.89 2.03 13.51 621
2/0 67.43 19×2.12 2.03 14.66 778
3/0 85.01 19×2.39 2.03 16.01 934
4/0 107.2 19×2.68 2.03 17.46 1159
250 127 37×2.09 2.41 19.45 1368
300 152 37×2.29 2.41 20.85 1623
350 177 37×2.47 2.41 22.11 1876
400 203 37×2.64 2.41 23.3 2128
500 253 37×2.95 2.41 25.47 2631
600 304 37×3.23 2.79 28.19 3174
650 329 37×3.37 2.79 29.17 3345
700 355 37×3.49 2.79 30.01 3609

Based on 40℃ ambient air temperature.

The above information is from the following sources:

•   IEC 60287  Electric cables – Calculation of the current rating (all Parts)

•   IEC 60364  Electrical installations of buildings

•   IEC 60228  Conductors of insulated wire cables

Testing Picture

air aging box conductor DC reistance test equipmentecentricty measurement equipment

Product Categories : Electrical Wire Cable

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Crazy Zhang Mr. Crazy Zhang
What can I do for you?
Contact Supplier