Huayuan Gaoke Cable Co.,Ltd.
Inorganic Mineral Insulated Power Cable,Hospital Mansion Plaza Hotel with Fire Protection Power Cable,Flexible Fireproof Cable
Payment Type: | L/C,T/T,D/P,Paypal,Money Gram,Western Union |
---|---|
Incoterm: | FOB,CFR,CIF,FCA,CPT,CIP |
Min. Order: | 1000 Meter |
Model No.: Fire Proof Cable
Brand: HUAYUAN YONGTONG
Type: Insulated
Conductor Type: Stranded
Conductor Material: Copper
Sheath Material: Crosslinking
Insulation Material: XLPE
Material Shape: Round Wire
Range of Application: LSOH
Certification: ISO9001
Brand: HUAYUAN YONGTONG
Packaging: FULL WOODEN DRUMS
Productivity: 1000KM/YEAR
Transportation: Ocean,Land,Air
Place of Origin: BEIJING,CHINA
Supply Ability: 100KM/MONTH
Certificate: CE,CCC,ISO
HS Code: 8544601200
Port: Tianjin Port,Shanghai Port,Qingdao Port
Payment Type: L/C,T/T,D/P,Paypal,Money Gram,Western Union
Incoterm: FOB,CFR,CIF,FCA,CPT,CIP
Fire Proof Cable Super Multi Core Inorganic Mineral Insulated Corrugated Copper and LSHF Sheathed Cable
Fire-resistant property
(1) According to national standards, fire-resistant wire and cable fire test method characteristic
test, according to GB12666.6
Class A, burn in fire with flame temperature 950°C, apply voltage of 750V between phase and
phase and between phase and outer sheath,it should be able to withstand for 90min without
breakdown.
Class B, bun in fire with flame temperature 750-800°C, apply voltage of 750V between phase
and phase and between phase and outer sheath,it should be able to withstand for 90min without
breakdown.
(2) According to the BS6378,flexible fireproof cable satisfies the following requirements:
Class A 650°C 3h
Class B 750°C 3h
Class C 950°C 3h
Class S 950°C 20min
Electrical characteristics
(1) Rated voltage: 0.6/1kV
(2) Rated working voltage: light load 500V, heavy load 750V;
(3) Rated current: single-core 25A-1,800A: multi-core 16A-500A;
(4) Insulation resistance: insulation resistance≥ 1000MΩkm. Cable length less than 100m,
then the insulation resistance≥ 10000MΩ;
(5) Power frequency withstand voltage: apply voltage of 2,000V and 2,500V between phase
and phase as well as phase and copper sheath of cables of 500V and 750V respectively,
they should be able to withstand for 15min without being broken down.