Huayuan Gaoke Cable Co.,Ltd.
High Voltage 110kv Power Cable,4mm2 Dc Solar Cable,Aerial Twisted Cable
Payment Type: | L/C,T/T,D/P,Western Union |
---|---|
Incoterm: | FOB,CFR,CIF,FCA,CPT |
Min. Order: | 1000 Meter |
Model No.: N2XS(F)2Y
Brand: HUAYUAN YONGTONG
Type: Insulated
Conductor Type: Stranded
Application: Overhead
Conductor Material: Copper
Sheath Material: Crosslinking
Insulation Material: XLPE
Material Shape: Round Wire
Range of Application: Refractory
Certification: ISO9001
Brand: HUAYUAN YONGTONG
Packaging: Drums
Productivity: 500kilometers/month
Transportation: Ocean,Land,Air
Place of Origin: Beijing,China
Supply Ability: 500kilometers/month
Certificate: CE, CCC, ISO
HS Code: 8544601400
Port: Shanghai Port,Tianjin Port,Qingdao Port
Payment Type: L/C,T/T,D/P,Western Union
Incoterm: FOB,CFR,CIF,FCA,CPT
Long-term operation temperature of cable conductor: 90°C;
In short-circuit (within 5S: max. temperature of conductor is not more than 250°C.
U0/U(Um) | Nominal System Voltage kV | Maximum Working Voltage kV | Lightning Impulse Withstand Voltage | Switching Impulse Withstand Voltage |
38/66(72.5) | 66 | 72.5 | 342 |
|
48/66(72.5) | 66 | 72.5 | 342 |
|
64/110(126) | 110 | 126 | 550 |
|
76/132(145) | 132 | 145 | 640 |
|
127/220(252) | 220 | 252 | 1050 |
|
160/275(300) | 275 | 300 | 1050 | 850 |
190/330(362) | 330 | 362 | 1175 | 950 |
220/400(420) | 400 | 420 | 1425 | 1050 |
290/500(550) | 500 | 550 | 1550 (Peak Value) |
Remark
1. System Frequency is 50Hz
2. During Normal Operation, Allowable Maxi Cable Conductor Temperature is 90°C
3. During short circuit (short circuit duration no more than 5S), Max. Cable Conductor Temperature is 250°C.
4. Cable Service Life is at least 30 Years.
5. No drop restrictions during cable laying. The ambient temperature should be Min 0°C, or it should be heated before being laid.
6. Allowable Max. Pulling force for conductor Cu cable: 70N/mm2 Al cable: 40N/mm2
7. Allowable side pressure Max. 5kN/m.
8. The minimum bend radius is 20D during laying, and 15D during operation.
Enviromental Conditions
1.Rated Voltage 0.6/1kV PVC Insulation Power Cable :
The long-term working temperature of cable conductor should be not more than 70°C.
While short-circuit the highest working temperature of cable conductor should be not more than 160°C(5 seconds maximum duration);
The minimum bending radius for laying cable(D is diameter):single core unarmoured cable should be 20D,multi-core unarmoured cable should be 15D,single core armoured cable should be 15D,multi-core armoured cable should be 12D;
The environment temperature for laying cable should be not less than 0°C.
2. Rated Voltage 0.6/1kV XLPE Insulation Power Cable / Rated Voltage 3.6/6~26/35kV XLPE Insulation Power Cable :
The long-term working temperature of cable conductor should be not more than 90°C.
While short-circuit the highest working temperature of cable conductor should be not more than 250°C(5 seconds maximum duration);
3. Rated Voltage 0.6/1kV and Frequency Inverter Control System Power Cable:
Designed with fully symmetric space structure, cable has excellent electromagnetic compatibility;
Low and uniform positive sequence and zero-sequence impedances have greatly improved power quality compared with ordinary four-core cable;
The environment temperature for laying cable; PVC and XLPE insulation is 0°C;
The maximum working temperature of cable; PVC insulation is 70°C,XLPE insulation is 90°C;
Low-smoke halogen-free flame retardant cable: PH value of burning gas ≥4.3,conductivity≤10us/mm, minimum light transmittance shall not be less than 60% while product burning;
The minimum bending radius for laying cable is 12D (D is diameter).
1.Underground Cable 2.Copper Wire Screened Cable 3.Electrical Cable Wires 4.High Voltage Power Cable 5.110kv Cable 6.132kv Cable
Product Categories : Fire-Proof Cable