http://www.bjhygkcable.com
Home > Products > Fire-Proof Cable > 0.6/1KV fire proof flame retardant electrical power cable

0.6/1KV fire proof flame retardant electrical power cable

    Payment Type: L/C,T/T,D/P,Paypal,Western Union
    Incoterm: FOB,CFR,CIF,FCA,CPT
    Min. Order: 1000 Kilometer
Basic Info

Model No.vv

BrandHUAYUAN YONGTONG

ApplicationUnderground

VoltageLow and Medium Voltage Cable

CurrentAC Cable

Insulation MaterialXLPE

Sheath MaterialCrosslinking

Material ShapeRound Wire

Wire Core MaterialBare Copper Wire

CertificationISO

ModelYJV

BrandHUAYUAN YONGTONG

Additional Info

PackagingDrums

Productivity500kilometers/month

TransportationOcean,Land,Air

Place of OriginBeijing,China

Supply Ability500kilometers/month

CertificateCE,ISO,CCC

HS Code8544609090

PortTianjin Port,Shanghai Port,Beijing

Payment TypeL/C,T/T,D/P,Paypal,Western Union

IncotermFOB,CFR,CIF,FCA,CPT

Product Description

0.6/1KV flame proof retardant cable

 

Rated voltage: 0.6/1kv 

Nominal cross sectional area of conductor: 1.5~400mm2 

Standard

The product is manufactured according to the standard of GB12796-91 and GB 12666.5-90  or IEC,BS,DIN and ICEA upon request. 

Applications

The product  is suitable for use in power distribution lines with rated power -frequency voltage up to and including  0.6/1kV

 

Operating characteristics

1, Rated power-frequency voltage Uo/U :0.6/1 kV

2,Max.permissible continuous operating temperature of conductor: 90 

3,Max.short-circuit temperature of conductor shall not exceed 250.(5s maximum duration ).

4,The ambient temperature under installation should not below 0 

5,The flame retardant performance of cable is in according with A or C grade request of GB 12666.5-90

6,The low smoke and non-halo of cable is in according with IEC60751 

7,When end product burning ,PH value and conductivity of insulation and sheath material should suit infra-table regulate.

8.The low smoke and non-halo of cable is in according with IEC61034

9,When end product burning, the minimum light transmittance should not less than 30%

10, The bending radius of cable should not less than 15 times of the cable diameter

Fire Rated Cable Shielded Plenum Fire Alarm CableFire Alarm Cable

Advanced Manufacturing Equipments

Product EquipmentOutdoor Warehouse for Finished CableXLPE-Insulated-Armoured-PVC-Sheathed-Power-Cable (1)


TEST REPORT

BASEC-1BASEC-2BASEC-3BASEC-4BASEC-5

1.Coppe Fire Cable  2. Mica Tape Insulated Cable  3.Fire Resistant Cable  4.Fire-Proof Cable  5.Flame Retardant Cables  6.Insulated Fire Retardant Cable

Product Categories : Fire-Proof Cable

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Crazy Zhang Mr. Crazy Zhang
What can I do for you?