http://www.bjhygkcable.com
Home > Products > Fire-Proof Cable > Low Voltage 0.6/1KV Fire Proof Electric Cable and networkas Power Engineering Device

Low Voltage 0.6/1KV Fire Proof Electric Cable and networkas Power Engineering Device

    Payment Type: L/C,T/T,D/P,Western Union
    Incoterm: FOB,CFR,CIF,FCA,CPT
    Min. Order: 1000 Meter

Download:

Basic Info

Model No.YJLV

BrandHUAYUAN YONGTONG

ApplicationConstruction

VoltageLow and Medium Voltage Cable

CurrentAC Cable

Insulation MaterialXLPE

Sheath MaterialPVC

Material ShapeRound Wire

Wire Core MaterialBare Copper Wire

CertificationISO

ModelYJLV22

BrandHUAYUAN YONGTONG

Additional Info

Packaging DRUMS

Productivity100KM/M

TransportationOcean,Land,Air

Place of OriginBEIJING CHINA

Supply Ability100KM/M

CertificateCE,ISO,CCC

HS Code8544601200

PortTianjin Port,Shanghai Port,Qingdao Port

Payment TypeL/C,T/T,D/P,Western Union

IncotermFOB,CFR,CIF,FCA,CPT

Product Description
BASEC-1

BASEC-2BASEC-3BASEC-4BASEC-50.6/1KV Fireproof Cable Inorganic Mineral Insulated Metallic Sheath

0.6/1KV flame proof retardant cable

Rated voltage: 0.6/1kv

Nominal cross sectional area of conductor: 1.5~400mm2

Standard

The product is manufactured according to the standard of GB12796-91 and GB 12666.5-90  or IEC,BS,DIN and ICEA upon request.

Applications

The product  is suitable for use in power distribution lines with rated power -frequency voltage up to and including  0.6/1kV

Operating characteristics

1, Rated power-frequency voltage Uo/U :0.6/1 kV 

2,Max.permissible continuous operating temperature of conductor: 90

3,Max.short-circuit temperature of conductor shall not exceed 250.(5s maximum duration ).

4,The ambient temperature under installation should not below 0

5,The flame retardant performance of cable is in according with A or C grade request of GB 12666.5-90

6,The low smoke and non-halo of cable is in according with IEC60751

7,When end product burning ,PH value and conductivity of insulation and sheath material should suit infra-table regulate. 

8.The low smoke and non-halo of cable is in according with IEC61034

9,When end product burning, the minimum light transmittance should not less than 30% 

10, The bending radius of cable should not less than 15 times of the cable diameter.

Test project

BS6387

GB/T 12666.6

IEC331

Burn

A(Level A): 650±40℃,180min

B(Level B): 750±40℃,180min

C(Level C): 950±40℃,180min

S(Level S): 950±40℃,20min

A(Type A):

950℃~1000℃90min

B(Type B):

750℃~850℃90min

750℃,3h

Spray

W(Level W): 650±40℃

Fire 15min,

Fire again and spray15min

burns for 15min, then

burns again and sprays 15min

No

No

Mechanical impact

X(Level X): 650±40℃,15min

Y(Level X): 750±40℃,15min

Z(Level Z ): 950±40℃,30 times within 15min

No

No

WDZA-YJY

NG-A(BTLY) 1KV (6)

Test

Test Equipment

package-2

BSI Certificate for Fire Resistant and BS

Location

The XLPE Insulation could be used in many kinds of cable, such as the Fire Resistant Cable, Fire-Proof Cable, Insulated Fire Retardant Cable, Flame Retardant Cables, Copper Fire Cable, Security Fire Alarm Cable, and so on.

Product Categories : Fire-Proof Cable

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Crazy Zhang Mr. Crazy Zhang
What can I do for you?
Contact Supplier