http://www.bjhygkcable.com
Home > Products > Flexible Welding Cable > 3.6/6KV~26/35KV XLPE Insulated Electric Cable

3.6/6KV~26/35KV XLPE Insulated Electric Cable

    Payment Type: L/C,T/T,D/P,Paypal,Money Gram,Western Union
    Incoterm: FOB,CFR,CIF,FCA,CPT
    Min. Order: 500 Meter
Basic Info

Model No.YJV32

BrandHUAYUAN YONGTONG

ApplicationConstruction

VoltageLow and Medium Voltage Cable

CurrentAC Cable

Insulation MaterialXLPE

Sheath MaterialCrosslinking

Material ShapeRound Wire

Wire Core MaterialBare Copper Wire

CertificationISO

BrandHUAYUAN YONGTONG

Additional Info

PackagingFULL STEEL DRUMS

Productivity500kilometers/month

TransportationOcean,Land,Air

Place of OriginBeijing, China

Supply Ability500kilometers/month

CertificateCE,CCC,ISO

HS Code8544601200

PortShanghai Port,Tianjin Port,Qingdao Port

Payment TypeL/C,T/T,D/P,Paypal,Money Gram,Western Union

IncotermFOB,CFR,CIF,FCA,CPT

Product Description

Product Standard

The product is manufactured according to the standard of IEC60502-2 [Extruded solid dielectric power cables for rated voltages from l KV (Um=1.2KV) to 35KV (Um=40.5KV)", BS, DIN and ICEA upon request.

Applications

The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6KV/6KV~26/35KV.

Operating Characteristics

Rated power-frequency voltage U0/U: 3.6/6KV~26/35KV.

Max. Permissible continuous operating temperature or conductor:90℃.

Max. short-circuit temperature of conductor shall not exceed 250℃. (5s maximum duration)

The ambient temperature under installation should not below 0℃.

The bending radius of a single-core cable should not less than 20 times of the cable diameter.

The bending radius of a three-core cable should not less than 15 times of the cable diameter.

Voltage Designation

The rated voltage of the cable for a given application shall be suitable for the operating conditions in the system in which the cable is used, and is expressed in the form of U0/U (Um) KV. Where:

U0-The rated power-frequency voltage between conductor and earth or metallic screen, for which the cable designed;

U-The rated power-frequency voltage between conductors, for which the cable designed;

Um-The maximum value of the [highest system voltage" for which the equipment may be used.

The values of U0 recommended for cables to be used in three-phase systems are listed below.

U

KV

Um

KV

U0*KV

system categories A and B

system categories C

6

7.2

3.6

6

10

12

6

8.7

15

17.5

8.7

12

20

24

12

18

30

36

18

-

35

40.5

21

26

System category A-This category comprises those systems in which any phase conductor that comes in contact with earth or an earth conductor, is disconnected from the system within 1 min.

System category B-This category comprises those system which under fault conditions, are operated for a short time with one phase earthed. This period should not exceed 1h. For a longer period, not exceeding 8h on any occasion, can be tolerated. The total duration of earth faults in any year should not exceed 125h.

System category C-This category comprises all systems which do not fall into categories A and B.

Type of Cable

Type

Designation

Application

YJV

Copper conductor, XLPE insulated and PVC Sheathed Power Cable.

For laying indoors, in tunnel or cable trench, unable to bear external mechanical forces, Single core cable in magnetic duct is not permissible.

YJLV

Aluminum conductor, XLPE insulated and PVC sheathed power cable.

YJY

Copper conductor, XLPE insulated and PE sheathed power cable.

YJLY

Aluminum conductor, XLPE insulated and PE sheathed power cable.

YJV22

Copper conductor, XLPE insulated, steel tape armored and PVC sheathed power cable.

For laying indoors, in tunnel, cable trench, or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force.

YJLV22

Aluminum conductor, XLPE insulated, steel tape armored and PVC sheathed power cable.

YJV23

Copper conductor, XLPE insulated, steel tape armored and PE sheathed power cable.

For laying indoors, in tunnel, cable trench, or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force

YJLV23

Aluminum conductor, XLPE insulated, steel tape armored and PE sheathed power cable.

YJV32

Copper conductor, XLPE insulated, steel wire armored and PVC sheathed power cable.

For laying indoors, in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force.

YJLV32

Aluminum conductor, XLPE insulated, steel wire armored and PVC sheathed power cable.

YJV33

Copper conductor, XLPE insulated, steel wire armored and PE sheathed power cable.

YJLV33

Aluminum conductor, XLPE insulated, steel wire armored and PE sheathed power cable.




Three Core XLPE Insulated Middle Voltage Electric Cable

Three Core XLPE Insulated Middle Voltage Power Cable Copper Conductor

XLPE Insulated Electrical Cable For Rated Voltage 3.6/6KV~26/35KV


Advanced Manufacturing Equipments

Product Equipment

 Advanced Testing Equipments    Guarantee High Quality Production

Test Equipment

 Packages

Packages 

  Our Honor

 We got trust and praise from all customers by outstanding quality and good reputation. To  providefirst-rate products and service for society is the pursuit of staffs of  our Company forever. The after-sale service department provides series of before-sale,selling and  after-sale, which solve the worries behind for customers and provide complete and rapid service  for customers. Customers' satisfaction is the best return for staffa of our Company.

Certificates


1.Low Voltage Power Cable  2.the Three Core Copper Conductor  3.the Copper Wire Screened Cable  4.Aluminium Cable  5.XLPE Control Cable  6.ABC Cable  





Product Categories : Flexible Welding Cable

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Crazy Zhang Mr. Crazy Zhang
What can I do for you?
Contact Supplier