http://www.bjhygkcable.com
Home > Products > High Voltage Power Cable > 230KV 3000mm2 XLPE Insulated electric wire high volt cable

230KV 3000mm2 XLPE Insulated electric wire high volt cable

    Payment Type: L/C,T/T,D/P,Western Union
    Incoterm: FOB,CFR,CIF,FCA,CPT
    Min. Order: 1000 Meter
Basic Info

Model No.YJLW02, YJLLW02

BrandHUAYUAN YONGTONG

TypeInsulated

Conductor TypeStranded

ApplicationUnderground

Conductor MaterialCopper

Sheath MaterialCrosslinking

Insulation MaterialXLPE

Material ShapeRound Wire

Range of ApplicationLSOH

CertificationISO9001

BrandHUAYUAN YONGTONG

Additional Info

PackagingDRUMS

Productivity100KM/M

TransportationOcean,Land,Air

Place of OriginBEIJING, CHINA

Supply Ability100KM/M

CertificateCE,ISO,CCC

HS Code8544601400

PortTianjin Port,Shanghai Port,Qingdao Port

Payment TypeL/C,T/T,D/P,Western Union

IncotermFOB,CFR,CIF,FCA,CPT

Product Description

Electric wire High-voltage 110~220KV XLPE Cable

1. The cross-linkage PE insulated and wrinkled aluminum wrapper waterproof PVC Sheathed Power Cable.

Type

YJLW02, YJLLW02

Specification

240mm2~3000mm2

Voltage

110~220KV

Usage

Suitable for the places with a higher underground water level and to be used underground, in the tunnels or pipes. Such cables bear a bigger pulling force and pressure.

 

2.The cross-linkage PE insulated and wrinkled aluminum wrapper waterproof PE sheathed power cable.

Type

YJLW02, YJLLW02

Specification

240mm2~3000mm2

Voltage

110~220KV

Usage

 

Suitable for the places with a higher underground water level and to be used underground, in the tunnels or pipes. Such cables bear a bigger pulling force and pressure.

 Specific property for usage of 110KV~220KV XLPE high-voltage cable:

1.       Cable`s conductor highest working temperature is allowed up to 90°C, and overload when meet an emergency is 130°C , When short circuit (in ≤5 seconds) the highest temperature is 250°C

2.       When installing or laying cable, the ambient temperature should be less than -20°C, and have to give a preheat to cable.

3.       The minimum bending diameter:

Cable type Bending  diameter

Metal sheathed

After laying

30D0

During laying

40D0

Note: In form, D0 is a real test value to cable`s outer diameter.

4.       Allowed biggest axial traction force to outer diameter when laying cable (not consider the radial lateral-pressure at bent set ion) T=K×core NO. ×section (kg), in formula, the coefficient K value should be: the copper core get 7, the aluminum core get 4.

5.       Allowed biggest lateral-press P, when cable is being bent

The single core cable is required P≤500kg/m.

P=T/R (T is indicated axial traction force; R is indicated radius of bent-wheel), Knowing from above formula, as the traction force is made up by length and weight of cable. So it lets P to applying requirement as above. Then the diameter of bent-wheel should be widened.

6.       Cable laying is not being restricted by drop.

110kv~220kv XLPE Extra High Voltage Cable Outdoor Power Cable YJLLW02


132KV AND BELOW XLPE EXTRUDING LINE ONE

66KV HV CABLE radiation11

high voltage cable project 2

220kv out door cable compond type terminationshigh voltage cable project 1

JOBSITE FOR 500KV XLPE CABLE AND ACCESSORIES SYSTEMS COMMISSIONG TEST

220KV 1X1600SQMM CABLE LAYING OUT IN BEIJING

Usage


1.High Voltage Power Cable  2.HV XLPE Cable  3.230kv XLPE Cable  4.Electrical Cable Wires  5.ConstructionCable  

Product Categories : High Voltage Power Cable

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Crazy Zhang Mr. Crazy Zhang
What can I do for you?
Contact Supplier