Huayuan Gaoke Cable Co.,Ltd.
High Voltage XLPE Insulated MV Power Cable,Single Core HV XLPE Insulated Electric Cable,For Underground Power Transimission Cable
Payment Type: | L/C,T/T,D/P,Western Union |
---|---|
Incoterm: | FOB,CFR,CIF,FCA,CPT |
Min. Order: | 1000 Meter |
Model No.: YJLW02, YJLLW02
Brand: HUAYUAN YONGTONG
Type: Insulated
Conductor Type: Stranded
Application: Underground
Conductor Material: Copper
Sheath Material: Crosslinking
Insulation Material: XLPE
Material Shape: Round Wire
Range of Application: LSOH
Certification: ISO9001
Brand: HUAYUAN YONGTONG
Packaging: DRUMS
Productivity: 100KM/M
Transportation: Ocean,Land,Air
Place of Origin: BEIJING, CHINA
Supply Ability: 100KM/M
Certificate: CE,ISO,CCC
HS Code: 8544601400
Port: Tianjin Port,Shanghai Port,Qingdao Port
Payment Type: L/C,T/T,D/P,Western Union
Incoterm: FOB,CFR,CIF,FCA,CPT
Electric wire High-voltage 110~220KV XLPE Cable
1. The cross-linkage PE insulated and wrinkled aluminum wrapper waterproof PVC Sheathed Power Cable.
Type | YJLW02, YJLLW02 |
Specification | 240mm2~3000mm2 |
Voltage | 110~220KV |
Usage | Suitable for the places with a higher underground water level and to be used underground, in the tunnels or pipes. Such cables bear a bigger pulling force and pressure. |
2.The cross-linkage PE insulated and wrinkled aluminum wrapper waterproof PE sheathed power cable.
Type | YJLW02, YJLLW02 |
Specification | 240mm2~3000mm2 |
Voltage | 110~220KV |
Usage |
Suitable for the places with a higher underground water level and to be used underground, in the tunnels or pipes. Such cables bear a bigger pulling force and pressure. |
Specific property for usage of 110KV~220KV XLPE high-voltage cable:
1. Cable`s conductor highest working temperature is allowed up to 90°C, and overload when meet an emergency is 130°C , When short circuit (in ≤5 seconds) the highest temperature is 250°C
2. When installing or laying cable, the ambient temperature should be less than -20°C, and have to give a preheat to cable.
3. The minimum bending diameter:
Cable type Bending diameter | Metal sheathed |
After laying | 30D0 |
During laying | 40D0 |
Note: In form, D0 is a real test value to cable`s outer diameter.
4. Allowed biggest axial traction force to outer diameter when laying cable (not consider the radial lateral-pressure at bent set ion) T=K×core NO. ×section (kg), in formula, the coefficient K value should be: the copper core get 7, the aluminum core get 4.
5. Allowed biggest lateral-press P, when cable is being bent
The single core cable is required P≤500kg/m.
P=T/R (T is indicated axial traction force; R is indicated radius of bent-wheel), Knowing from above formula, as the traction force is made up by length and weight of cable. So it lets P to applying requirement as above. Then the diameter of bent-wheel should be widened.
6. Cable laying is not being restricted by drop.
1.High Voltage Power Cable 2.HV XLPE Cable 3.230kv XLPE Cable 4.Electrical Cable Wires 5.ConstructionCable