Huayuan Gaoke Cable Co.,Ltd.
Copper XLPE Insulated Cable,For Tunnel and Subway Cable,For Underground Power and Power Plant Cable
Payment Type: | L/C,T/T,D/P,Western Union |
---|---|
Incoterm: | FOB,CFR,CIF,FCA,CPT,CIP |
Min. Order: | 1000 Meter |
Model No.: YJLW02
Brand: HUAYUAN YONGTONG
Type: Insulated
Conductor Type: Stranded
Application: Underground
Conductor Material: Copper
Sheath Material: Crosslinking
Insulation Material: XLPE
Material Shape: Round Wire
Range of Application: LSOH
Certification: ISO9001
Brand: HUAYUAN YONGTONG
Packaging: DRUMS
Productivity: 100KM/M
Transportation: Ocean,Land,Air
Place of Origin: BEIJING, CHINA
Supply Ability: 100KM/M
Certificate: CE,ISO,CCC
HS Code: 8544601300
Port: Tianjin Port,Shanghai Port,Qingdao Port
Payment Type: L/C,T/T,D/P,Western Union
Incoterm: FOB,CFR,CIF,FCA,CPT,CIP
1 Description
Construction: Compacted stranded circular or segmental copper or aluminium conductor, extruded semi-conducting compound as conductor screen, cross-linked polyethylene(XLPE) insulation, semi-conducting compound as insulation screen, semi-conducting water blocking tape, corrugated aluminium sheath, PE or PVC outer sheath.
The XLPE Insulation could be used in many cables, such as the Fire Alarm Cable, Security Fire Alarm Cable, Fire-Proof Cable, Fire Resistanve Cable, Control Cable, Mica Tape Insulation Cable, 0.6kv Cable, XLPE Control Cable and so on.
2 Operating Characteristics
Rated voltage U0/U(Um): 76/132(145)kV
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the [highest system voltage" for which the equipment may be used.
Max. permissible continuous operating temperature of conductor: 90 °C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250 °C
The ambient temperature under installation should not be lower than: 0 °C
The bending radius of cable: not less than 20 times of the diameter of cable
3 Application
The cable is laid indoors, outdoors, in tunnel, in cable trench, or direct in ground, able to bear external mechanical force and certain pulling force.
4 Manufacturing Standards
IEC 60840, IEC 62067, GB/T 11017, GB/Z 18890
Type | Description | Number of cores | Nominal cross section of conductor (mm2) | ||
38/66kV | 64/110kV 76/132kV | 127/220kV | |||
YJLW02 | CU/XLPE/Corrugated Aluminium/PVC | 1 | 150~2500 | 240~2500 | 400~2500 |
YJLLW02 | AL/XLPE/Corrugated Aluminium/PVC | ||||
YJLW03 | CU/XLPE/Corrugated Aluminium/PE | 1 | 150~2500 | 240~2500 | 400~2500 |
YJLLW03 | AL/XLPE/Corrugated Aluminium/PE | ||||
YJLW02-Z | CU/XLPE/Corrugated Aluminium/PVC Longitudinal Waterproof | 1 | 150~2500 | 240~2500 | 400~2500 |
YJLLW02-Z | AL/XLPE/Corrugated Aluminium/PVC Longitudinal Waterproof | ||||
YJLW03-Z | CU/XLPE/Corrugated Aluminium/PE Longitudinal Waterproof | 1 | 150~2500 | 240~2500 | 400~2500 |
YJLLW03-Z | AL/XLPE/Corrugated Aluminium/PE Longitudinal Waterproof |