http://www.bjhygkcable.com
Home > Products > High Voltage Power Cable > 132 kV XLPE Insulated HV Power Cable

132 kV XLPE Insulated HV Power Cable

    Payment Type: L/C,T/T,D/P,Western Union
    Incoterm: FOB,CFR,CIF,FCA,CPT,CIP
    Min. Order: 1000 Meter
Basic Info

Model No.YJLW02

BrandHUAYUAN YONGTONG

TypeInsulated

Conductor TypeStranded

ApplicationUnderground

Conductor MaterialCopper

Sheath MaterialCrosslinking

Insulation MaterialXLPE

Material ShapeRound Wire

Range of ApplicationLSOH

CertificationISO9001

BrandHUAYUAN YONGTONG

Additional Info

PackagingDRUMS

Productivity100KM/M

TransportationOcean,Land,Air

Place of OriginBEIJING, CHINA

Supply Ability100KM/M

CertificateCE,ISO,CCC

HS Code8544601300

PortTianjin Port,Shanghai Port,Qingdao Port

Payment TypeL/C,T/T,D/P,Western Union

IncotermFOB,CFR,CIF,FCA,CPT,CIP

Product Description

1 Description

Construction: Compacted stranded circular or segmental copper or aluminium conductor, extruded semi-conducting compound as conductor screen, cross-linked polyethylene(XLPE) insulation, semi-conducting compound as insulation screen, semi-conducting water blocking tape, corrugated aluminium sheath, PE or PVC outer sheath.
The XLPE Insulation could be used in many cables, such as the Fire Alarm Cable, Security Fire Alarm Cable, Fire-Proof Cable, Fire Resistanve Cable, Control Cable, Mica Tape Insulation Cable, 0.6kv Cable, XLPE Control Cable and so on.

2 Operating Characteristics
Rated voltage U0/U(Um): 76/132(145)kV
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the [highest system voltage" for which the equipment may be used.
Max. permissible continuous operating temperature of conductor: 90 °C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250 °C
The ambient temperature under installation should not be lower than: 0 °C
The bending radius of cable: not less than 20 times of the diameter of cable

3 Application
The cable is laid indoors, outdoors, in tunnel, in cable trench, or direct in ground, able to bear external mechanical force and certain pulling force.

4 Manufacturing Standards

IEC 60840, IEC 62067, GB/T 11017, GB/Z 18890

 

Type

Description

Number of cores

Nominal cross section of conductor (mm2)

38/66kV

64/110kV 76/132kV

127/220kV

YJLW02

CU/XLPE/Corrugated Aluminium/PVC

1

150~2500

240~2500

400~2500

YJLLW02

AL/XLPE/Corrugated Aluminium/PVC

YJLW03

CU/XLPE/Corrugated Aluminium/PE

1

150~2500

240~2500

400~2500

YJLLW03

AL/XLPE/Corrugated Aluminium/PE

YJLW02-Z

CU/XLPE/Corrugated Aluminium/PVC Longitudinal Waterproof

1

150~2500

240~2500

400~2500

YJLLW02-Z

AL/XLPE/Corrugated Aluminium/PVC Longitudinal Waterproof

YJLW03-Z

CU/XLPE/Corrugated Aluminium/PE Longitudinal Waterproof

1

150~2500

240~2500

400~2500

YJLLW03-Z

AL/XLPE/Corrugated Aluminium/PE Longitudinal Waterproof

 132kv XLPE Power Cable PE and PVC Outer Sheath Uhv Cable

132KV AND BELOW XLPE EXTRUDING LINE ONE

132kv cable and accessories out door terminaionts in stalled in door

110kv out door terminations and lightening arresters

110kv cable processed for cable accessories installations

132kv out door terminations and lightening arresters

110KV cable

company instruction

Product Categories : High Voltage Power Cable

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Crazy Zhang Mr. Crazy Zhang
What can I do for you?
Contact Supplier