Model No.YJV

BrandHUAYUAN YONGTONG

ApplicationConstruction

VoltageLow and Medium Voltage Cable

CurrentAC Cable

Insulation MaterialPVC

Sheath MaterialPVC

Material ShapeRound Wire

Wire Core MaterialBare Copper Wire

CertificationISO

BrandHUAYUAN YONGTONG

Additional Info

PackagingDrums

Productivity100KM/M

TransportationOcean,Land,Air

Place of OriginBEIJING,CHINA

Supply Ability100KM/M

CertificateCE,CCC,ISO

HS Code8544601200

PortTianjin Port,Shanghai Port,Qingdao Port

Payment TypeL/C,T/T,D/P,Western Union

IncotermFOB,CFR,CIF,FCA,CPT

Product Description

TECHNICLA DATA SHEET FOR 6 kV 3C 120 SQmm POWER CABLE

NO. ITEM  UNIT DATA
1 Name of Manufacturer: Beijing Huayuan Gaoke
Cable Co.,Ltd. 
1.2 Country of Manufacturer:  China 
2 Which type of manufacturing process viz. Continuous Catanery Vulcanisation (CCV) or vertical Catanery Vulcanisation system (VCV) or horizontal MDCV will be used to ensure circularity and concentricity of the extruded layers around the conductor. CCV
3 Type of Cable: Cu/PVC/CTS/PVC/STA.PVC
4 Rated nominal voltage kV 3.6/6
5 Rated Maximum voltage kV 7.2
6 Nominal cross-sectional area of Conductor Sq.mm 120
7 Conductor
7.1 Material Copper
7.2  Shape & formation Round
7.3  Diameter of conductor  mm 13
7.4 Dia.Of Single Wire/Number of strands mm 2.87/19
8 Insulation
8.1 Material PVC
8.2 Insulation Thickness(Min.Avg.) mm 3.4
8.3 Diameter of Insulation(Approx.) mm 19.8
10  Metallic Screen:
10.1 Material Plain Annealed Copper Tape
10.2 Thickness of the copper tape screen mm 0.1
10.3  Diameter of the cable across the metallic screen(Approx.) mm 20.1
12 Filler
12.1 Material Extrusion PVC
12.2 Diameter of Laid-Up Core 44.9
13 Armouring
13.1 Material galvanized steel tape
13.2 Approximate thickness/layer mm/ 0.5/2
13.3 Diameter of armouring (Approx.) mm 46.9
14 Outer Sheath
14.1 Material PVC
14.2 Outer Sheath Thickness(Nominal) 2.6
14.3 Over Diameter(Approx.) 52.1
15 Conductor Weight kg/km 3141
15.1 Total Cable Weight (Approx.) kg/km 6210
16 Minimum Bending Radius
16.1 During Installation mm 650
16.2 Installed mm 800
17 Maximum Pulling Tension
17.1 Of Conductor kN 25.2
18  Continuous current rating under the specified installation and operating conditions.    Conductor temperature 90° C    . Ground    temperature 35° C    and    depth    of laying 1500 mm
18.1 In Air Amp 312
18.2 In Ground Amp 237
18.3 In pipeline Amp 205
19 Maximum value of electric stresses at the conductor screen (Calculation to be shown separately)  kV/mm  1.32
19.1 Maximum value of dielectric stress at the insulation  kV/mm  0.86
20 Short circuit capacity of conductor for 1/2/3    second assuming    conductor temperature of 90 ° C prior to short    circuit and 140 ° C during short circuit
20.1 1.0 Secs kA 11.5
20.2 2.0 Secs kA 8.2
20.3 3.0 Secs kA 6.7
21 Short circuit capacity of metallic screen    for    1/2/3 second     at     screen temperature of 80 ° C prior to short circuit    and 120 ° C during short circuit
21.1 1.0 Secs kA 2.6
21.2 2.0 Secs kA 1.9
21.3 3.0 Secs kA 1.5
22 Screen voltage under maximum operating conditions assuming all circuits connected kV per km 0.05
23 TEST
23.1 Maximum D.C. resistance of conductor  per km. at 20 degree C.  Ohm 0.153
23.2 Maximum A.C. resistance of conductor per km. at 80 degree C.  Ohm 0.191
23.3  Maximum electrostatic capacitance per km. of cable. μF 0.913
23.4 Partial discharge at 1.50 Uo pc ≤ 10
23.5 A.C.  Enduring Test voltage 2.5U0/ hours  kV/mim 12.5/5
23.6 D.C.Out sheath  Enduring Test voltage  kV/mim 5kV/1min
23.7 Impulse test voltage kV 60
24 Approximate drum dimension (dia & width) mm/mm 2000*1400
25 Maximum length of cable in a drum (Metres) m 550
26 Minimum length of cable in a drum  (Metres) m 500
27 Approximate gross weight of cable in a drum  TON 3.3
28 Expected Cable life. Year 30

 Drawing of Configuration 

Cu/LPE/AWA/PVC 6.35/11 (12) kV 3×95mm2

 

 

Cu/LPE/AWA/PVC 6.35/11 (12) kV   3×95mm2

Construction

Thickness(mm)

Diameter(mm)

1 --- Copper Conductor

 

 13.0(+0.1,-0.1)

2 --- PVC insulation

3.4

19.8(+0.5,-0.5)

3 --- Copper tape screen

0.1

 20.1

4 --- PVC filler

 

 44.9

5 --- Galvanized steel tape

0.5

 46.9

6--- PVC outer sheath

2.6

52.1(+2.0,-2.0)


Advanced Manufacturing Equipments

Product Equipment


 Advanced Testing Equipments  

      The company introduced the world's advanced level wire & cable production and testing equipment, such as DV-6E spectrum analyzer, online micro pore impurity tester, etc. 

        Advanced Testing Equipment     Guarantee High Quality Production

Test Equipment


Foreign Customers in our Factory

 Packages

Packages 

  Our Honor

 We got trust and praise from all customers by outstanding quality and good reputation. To  providefirst-rate products and service for society is the pursuit of staffs of  our Company forever. The after-sale service department provides series of before-sale,selling and  after-sale, which solve the worries behind for customers and provide complete and rapid service  for customers. Customers' satisfaction is the best return for staffa of our Company.

Certificates


1.Middle Voltage Power Cable  2.Three Core Copper Conductor  3.Five Core Copper Conductor  4.MV XLPE Cable  5.Copper Wire Screened Cable  5.PVC Single Core Cable  

 

Product Categories : PVC Insulated Power Cable

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Crazy Zhang Mr. Crazy Zhang
What can I do for you?
Contact Supplier