Model No.: YJLV22
Brand: HUAYUAN YONGTONG
Application: Construction
Voltage: Low and Medium Voltage Cable
Current: DC Cable
Insulation Material: XLPE
Sheath Material: Crosslinking
Material Shape: Round Wire
Wire Core Material: Bare Copper Wire
Certification: ISO
Model: YJLV22
Brand: HUAYUAN YONGTONG
Packaging: Drum
Productivity: 100KM/M
Transportation: Ocean,Land,Air
Place of Origin: Beijing,China
Supply Ability: 100KM/M
Certificate: CE,ISO,CCC
Port: Tianjin Port,Shanghai Port,Qingdao Port
Payment Type: L/C,T/T,D/P,Paypal,Money Gram,Western Union
Incoterm: FOB,CFR,CIF,FCA,CPT
Application: The Medium Voltage Type and XLPE Jacket SWA Armoured cable is suitable to be installed in transmission and distribution lines.
Standard: IEC, BS, ASTM, AS/NZS, IS and other standards as customers' required.
Characteriestics:
1)Max. operating temp. of the cable conductor is 90˚C.
2)Max. short circuit temp. of the cables conductor shall not exceed 250˚C.(max. duration not exceed 5s)
3)There are three kinds of rated voltage (U0) according to the ground fault duration, see the following table.
Type A: when any phrase conductor of this system connected to ground or earthed conductor, it can be separated with the system within 1minute.
Type B: when single phrase grounded of this system,it can run short time. The grounded time should not exceed 1 hour. cables under this system should not run over 8 hours In Soiled fault situation and the total continue fault grounded time of one year should not exceed 125 hours.
Type C: included all systems excluded in A & B.
4) When laying the cables at the ambient temp. of 0˚C and above, there is no need to pre-heat.
Max. Voltage of System(Um/kV) | Rated Voltage(U0)/kV | |
Type A & B | Type C | |
7.2 | 3.6 | 6.0 |
12 | 6.0 | 8.7 |
17.5 | 8.7 | 12.0 |
24.0 | 12.0 | 18.0 |
36.0 | 18.0 | - |
40.5 | 21 | 26 |
Note:
According to clients` requirements, our company can manufacture flame-retardant, fire-resistant, anti-termite, low smoke and halogen free, water blocking cables.
CONSTRUCTION:
1.Conductor
2.Conductor Screen
3.XLPE Insulation
4.Insulation Screen
5.Copper Tape Screen
6.Steel Wire Armored
7.Wrapping Tape
8.Separate Sheath
9.Outer Sheath
1.MV XLPE Cable 2.Steel Wire Armoured Cable 3.Steel Tape Armoured 4.Middle Voltage Power Cable 5.Gavanized Steel Wire 6.20kv Cable
Product Categories : Middle Voltage Power Cable