http://www.bjhygkcable.com
Home > Products > XLPE Power Cable > 23Kv 240mm2 300mm2 aluminum XLPE insulated cable

23Kv 240mm2 300mm2 aluminum XLPE insulated cable

    Payment Type: L/C,T/T,Paypal,Money Gram,Western Union
    Incoterm: FOB,CFR,CIF,FCA,CPT
    Min. Order: 1000 Meter
Basic Info

Model No.YJLSV

BrandHUAYUAN YONGTONG

ApplicationConstruction

VoltageLow and Medium Voltage Cable

CurrentAC Cable

Insulation MaterialXLPE

Sheath MaterialCrosslinking

Material ShapeRound Wire

Wire Core MaterialBare Copper Wire

CertificationISO

ModelYJLV22

BrandHUAYUAN YONGTONG

Additional Info

PackagingDrum

Productivity100km/M

TransportationOcean,Land,Air

Place of OriginBeijing,China

Supply Ability100km/M

CertificateCE,CCC,ISO

HS Code8544601200

PortTianjin Port,Shanghai Port,Beijing

Payment TypeL/C,T/T,Paypal,Money Gram,Western Union

IncotermFOB,CFR,CIF,FCA,CPT

Product Description

Product Name: 23Kv single core aluminum conductor XLPE insulated power cable

A

CABLE MANUFACTURER AND PROPOSER

 

A.1

Name

Beijing Huayuan Gaoke Co.,Ltd.

A.1.1

Address

Banbidian Village, Weishan Town, Daxing District




B

GUARANTEE PERIOD

Unit

Specified

Offered

B.1

Warranty period from the date of commissioning

month

18

 

 

 

 

 

 

 

B.2

Warranty period from the date of delivery of the Certificate of Receipt of Supply

month

24

 

 

 

 

 

 

 

ITEM

Description

Unit

Specified

Offered

C

CABLE TYPE

 

 

 

C.1

Type of cable

 

Single pole

Single core

 

 

 

 

 

 

D

CABLE  DESIGNATION

 

 

 

D.1

Designation of cable type according to manufacturer's catalog

 

By proposer

YJLSV 18/30 kV

 

 

 

 

 

 

E

APPLICABLE STANDARDS

 

 

 

E.1

Manufacturing and testing standard that complies with the cable offered

 

IEC 60502 - 2

IEC 60502-2

E.2

The type of cable offered has been successfully subjected to the type tests indicated in IEC 60502-2

 

Yes

YES

 

 

 

 

 

 

F

CABLE MAIN FEATURES

 

 

 

F.1

Nominal voltage  between phases

kV

23

23

F.2

Nominal voltage phase to ground

kV

13.3

13.3

F.3

Maximum system voltage

 

kV

25.8

25.8

F.4

Permissible current according to clauses 3.1.1 and 3.1.2 of the Technical Specifications

A

394

394(in ground,1 circuit ,phase spacing  100, flat formation, a point earthed,depth of laying 1200 mm ,thermal resistivity of soil 1.2 k.m/W,30℃)

F.5

Nominal Frequency

Hz

50

50

F.6

Daily load factor

%

50

≥50

F.7

Maximum operation temperature

°C

90

90

F.8

Short circuit capacity during 0,2 seconds

kA

15

≥15

 

 

 

 

 

 

G

CONSTRUCTIVE CHARACTERISTICS OF THE CABLE

 

 

 

G.1

Conductor features

 

 

 

G.1.1

Construction material

 

Aluminum

Aluminum

G.1.2

Total cross section

mm²

300

300

G.1.3

Number of wires

c/u

By proposer

37

G.1.4

Wires diameter

mm

By proposer

3.28(nominal)

G.1.5

External conductor diameter

mm

By proposer

20.5(nominal)

 

 

 

 

 

 

G.2

Screen over conductor

 

 

 

G.2.1

Screen material over conductor

 

Polyethylene semiconductor

Polyethylene semiconductor

G.2.2

Total screen  thickness over conductor

mm

By proposer

0.8(nominal)

 

 

 

 

 

 

G.3

Insulation

 

 

 

G.3.1

Insulation level

%

100

100

G.3.2

Insulation material

 

XLPE

XLPE

G.3.3

Average thickness

mm

By proposer

7.5

G.3.4

Minimum thickness

mm

By proposer

7.1

 

 

 

 

 

 

G.4

Screen over insulation

 

 

 

G.4.1

Material of screen over insulation

 

Polyethylene semiconductor

Polyethylene semiconductor

G.4.2

Thickness of the screen over insulation

mm

By proposer

0.6(nominal)

 

 

 

 

 

 

G.5

Metallic screen over insulation

 

 

 

G.5.1

Material  of the metallic screen

 

By proposer

copper wire

G.5.2

Cross section of the metallic screen

mm²

By proposer

48.2(calculated value)

 

 

 

 

 

 

G.6

External cover

 

 

 

G.6.1

Cover material

 

Thermoplastic PVC

Thermoplastic PVC

G.6.2

Average thickness

mm

By proposer

2.1

G.6.3

Minimum thickness

mm

By proposer

1.9

G.6.4

Color

mm

Red

Red

 

 

 

 

 

 

G.7

Characteristics of the finished cable

 

 

 

G.7.1

Nominal external diameter of cable

mm

By proposer

47.5

G.7.2

Nominal unit weight

kg/m

By proposer

2.51

G.7.3

Minimum bending radious of cable

mm

By proposer

855

G.7.4

Maximum mechanical stress allowed during installation

kN

By proposer

12.0

 

 

 

 

 

 

H

ELECTRICAL FEATURES OF CABLE ( see Note of item H.4)

 

 

 

H.1

Losses of one (1) three-phase circuit at nominal voltage and for the permissible current of the cable

 

 

 

H.1.1

Conductor losses at 90 ° C

kW/km.circ.

By proposer

20.03(I=394,per phase)

H.1.2

Dielectric losses insulation at 90 ° C

kW/km.circ.

By proposer

0.02

H.1.3

Total guaranteed losses

kW/km.circ.

By proposer

20.33(I=394,per ohase)

H.1.4

Power factor of insulation at nominal voltage and at 90 °C

%

By proposer

99.9

 

 

 

 

 

 

H.2

Electrical Parameters

 

 

 

 

H.2.1

Conductor ohmic resistance at 50 Hz and at 20 ° C

ohm/km

By proposer

0.101(AC)

H.2.2

Conductor ohmic resistance at 50 Hz and at 90 ° C

ohm/km

By proposer

0.130(AC)

H.2.3

Inductive Reactance at 50 Hz

ohm/km

By proposer

0.141

H.2.4

Capacitive Susceptance at 50 Hz

µS/km

By proposer

76.9

H.2.5

Inductive Reactance of zero secuence

ohm/km

By proposer

0.178

H.2.6

Capacitive Susceptance of zero secuence

µS/km

By proposer

  -J174

H.2.7

Ohmic resistance of the screen of cable in D.C. and 20°C

ohm/km

By proposer

0.36

 

 

 

 

 

 

H.3

Resisted Voltages for Electrical Tests

 

 

 

H.3.1

A.C. High Voltage  individual test , 5 min.

kV

47

47

H.3.2

A.C. High Voltage Test of sampling , 4 h.

kV

53

53

H.3.3

Partial discharge Test

kV

27

27

H.3.4

D.C. High Voltage  Test , after cable installation

kV

53

53

 

 

 

 

 

 

H.4

NOTE

 

 

 

 

 

The electrical characteristics must be applied for cables installed according to clause 3.1.2 of the technical specifications HLJ-LT-ETE-011

 

 

 

 

 

 

 

 

I

CABLE PACKING REELS

 

 

 

I.1

For " Las Juntas - Peuchén" line

 

 

 

I.1.1

Nominal length of continuous cable strip without joints

m

1000

1000

I.1.2

Nominal length of continuous cable strip without joints

m

800

800

I.1.3

Material from which the reel is made

 

Por Proponente

steel-wooden

I.1.4

Gross weight of reel including cable and lathing

kg

Por Proponente

2710

I.1.5

External diameter over lathing

cm

Por Proponente

100

I.1.6

Flange diameter

cm

Por Proponente

220

I.1.7

Drum diameter

cm

Por Proponente

220

I.1.8

Inside width between flanges

cm

Por Proponente

1040

I.1.9

External width

cm

Por Proponente

1200

I.1.10

Hole diameter for axis

cm

Por Proponente

160

I.1.11

Number of bolts of flanges

c/u

Por Proponente

2

Structure

30(36)Kv 1c240mm2

30(36)Kv 1c240mm2-1

30(36)Kv 1c300mm2

30(36)Kv 1c300mm2-1

Our factory

XLPE-Insulated-Armoured-PVC-Sheathed-Power-Cable (1)XLPE-Insulated-Armoured-PVC-Sheathed-Power-Cable (2)

Package and delivery

Workshop Picture

cantainer

Our honor

Certificates


1.MV XLPE Cable  2.Middle Voltage Power Cable  3.20kv Cable  4.Single Core Aluminium Conductor  5.Four Core Aluminium Conductor  


Product Categories : XLPE Power Cable

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Crazy Zhang Mr. Crazy Zhang
What can I do for you?
Contact Supplier