PVC Insulated and Outer Sheathed Power Cable,750V Class 5 Fine Annealed Copper Wire and Cable,KVV Power Cable
Payment Type: | L/C,T/T,D/P,Paypal,Money Gram,Western Union |
---|---|
Incoterm: | FOB,CFR,CIF,FCA,CPT,CIP |
Min. Order: | 1000 Bag/Bags |
Model No.: KVV
Brand: HUAYUAN YONGTONG
Type: Insulated
Conductor Type: Stranded
Application: Underground
Conductor Material: Copper
Sheath Material: PVC
Insulation Material: PVC
Material Shape: Round Wire
Range of Application: Flame Retardant
Certification: ISO9001
Brand: HUAYUAN YONGTONG
Packaging: Drum
Productivity: 1000km/M
Transportation: Ocean,Land,Air
Place of Origin: Beijing,China
Supply Ability: 1000km/M
Certificate: CE,CCC,ISO
HS Code: 8544609090
Port: Shanghai Port,Tianjin Port,Beijing
Payment Type: L/C,T/T,D/P,Paypal,Money Gram,Western Union
Incoterm: FOB,CFR,CIF,FCA,CPT,CIP
1. APPLICALBE STANDARDS
The cable which Beijing Huayuan offered shall be designed, manufactured and tested according to international standards as follows:
Quality Control Standard | |
ISO 9001 | Quality Management Systems |
ISO 14001 | Environmental Management Systems |
Component Material Standard | |
IEC 60228 | Conductors of insulated cables |
Cable Standard | |
IEC 60502-1 | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) – Part 1:Cables for rated voltages of 1kV(Um=1.2kV) and 3kV(Um=3.6kV) |
IEC 60227 | 450/750 V Polyvinyl chloride insulated cables |
IEC 60332-3-24 | Test for vertical flame spread of vertically-mounted bunched wires or cables – Category C |
2. CABLES STRUCTURE FOR 450/750V CABLE
1)
CU/PVC/CTS/PVC/STA/FR-PVC 450/750V 4C
Construction |
1-Conductor |
2--Insulation |
3--Filler |
4-Polyester tape |
5-Copper tape shield |
6-PVC Inner sheath |
7-Galvanized steel tape armour |
8-FR-PVC Outer sheath |
2)
CU/PVC/CTS/PVC/STA/FR-PVC 450/750V 7C
Construction |
1-Conductor |
2--Insulation |
3--Filler |
4-Polyester tape |
5-Copper tape shield |
6-PVC Inner sheath |
7-Galvanized steel tape armour |
8-FR-PVC Outer sheath |
3)
CU/PVC/CTS/PVC/STA/FR-PVC 450/750V 10C
Construction |
1-Conductor |
2--Insulation |
3--Filler |
4-Polyester tape |
5-Copper tape shield |
6-PVC Inner sheath |
7-Galvanized steel tape armour |
8-FR-PVC Outer sheath |
4)
CU/PVC/CTS/PVC/STA/FR-PVC 450/750V 14C
Construction |
1-Conductor |
2--Insulation |
3--Filler |
4-Polyester tape |
5-Copper tape shield |
6-PVC Inner sheath |
7-Galvanized steel tape armour |
8-FR-PVC Outer sheath |
5)
Flexible Conductor/PVC/CWBS/FR-PVC 450/750V 2C
Construction |
1-Conductor |
2-PVC insulation |
3-Filler |
4-Polyester tape |
5-Metal Shield |
6-Polyester tape |
7-FR-PVC Sheath |
6)
Flexible Conductor/PVC/CWBS/FR-PVC 450/750V 10C
Construction |
1-Conductor |
2-PVC insulation |
3-Filler |
4-Polyester tape |
5-Metal Shield |
6-Polyester tape |
7-FR-PVC Sheath |
7)
CU/XLPE/CTS/PVC/STA/FR-PVC 450/750V Instrumentation cables 2C
Construction |
1-Conductor |
2--Insulation |
3-- Polyester tape |
4--Filler |
5-Polyester tape |
6-Copper tape shield |
7-PVC Inner sheath |
8-Galvanized steel tape armour |
9-FR-PVC Outer sheath |
8)
CU/XLPE/CTS/PVC/STA/FR-PVC 450/750V Instrumentation cables 10C
Construction |
1-Conductor |
2--Insulation |
3-- Polyester tape |
4--Filler |
5-Polyester tape |
6-Copper tape shield |
7-PVC Inner sheath |
8-Galvanized steel tape armour |
9-FR-PVC Outer sheath |
3. TEST REQUIREMENTS FOR CONTROL CABLES
Test requirements for Control Cable, accordance with IEC standards.
4. PACKING PARTICULARS FOR CONTROL CABLES
The cables shall be wound on steel-wooden drums. The indelible marking shall be printed on the surface of drum flange in accordance with customer requirements.
Factory and Equipment:
Package:
Honor