Huayuan Gaoke Cable Co.,Ltd.
Steel Wire Armoured Electric Power Cable,Middle Voltage Three Core Copper Power Cable,Distribute Power in Power Transmission of the Cable
Payment Type: | L/C,T/T,D/P,Western Union |
---|---|
Incoterm: | FOB,CFR,CIF,FCA,CPT |
Min. Order: | 1000 Meter |
Model No.: YJV
Brand: HUAYUAN YONGTONG
Type: Insulated
Conductor Type: Stranded
Application: Underground
Conductor Material: Copper
Sheath Material: Crosslinking
Insulation Material: XLPE
Material Shape: Round Wire
Range of Application: LSOH
Certification: ISO9001
Brand: HUAYUAN YONGTONG
Packaging: DRUMS
Productivity: 100KM/M
Transportation: Ocean,Land,Air
Place of Origin: BEIJING,CHINA
Supply Ability: 100KM/M
Certificate: CE,CCC,ISO
HS Code: 8544601200
Port: Tianjin Port,Shanghai Port,Qingdao Port
Payment Type: L/C,T/T,D/P,Western Union
Incoterm: FOB,CFR,CIF,FCA,CPT
Three/Single Core Copper XLPE Insulated Steel Wire Armoured Electric Power Cable 6/10kV 6.35/11kV 12kV
Application:
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC Insulated Power Cable.
Using features:
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.
2. No. of core: Single-core, Three-core.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250.
4. D.C Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter.
7. Working Frequency Voltage Test:.
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable with Uo of 3.6kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
Power Cable
-Conductor: Solid or stranded copper
-Insulation: Cross-linked polyethylene( XLPE or PVC)
-Circuit Identication: The insulation shall be red, black
-Filler: Polypropylene lament with lapped binding tape
-Inner Sheath: Polyvinyl chloride (Black)
-Armor: Galvanized steel wire
-Core-covering: Binding tape
-Outer Sheath: Polyvinyl chloride (Black)
-Application: For use in ducts, trays and direct burial in ground. The cable is subject to immerse in water all the time.
-Standards / Testing Specications: IEC 60502-1.
Installation:
This cable can be installed in duct, tray or direct burial. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed,so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.
1. The products are mainly complying with IEC 60502 standard, also can be produced according to OEM requirements and other standards, such as BS standard, DIN standard, ASTM standard, etc.
Voltage grade is up to 35kv, cross-section area can be up to 400 sqmm (copper or aluminiun conductor). Conductor long-time operating temperature is 90 degrees. In short circuit, conductor highest temperature should be not more than 250 degrees.
2. Brief Construction:
Single core or multi-core
Copper or aluminium conductor
XLPE insulation
Copper tape or copper wire screen
Galvanized steel wire armored
PVC or PE sheath
1.Three Core Copper Conductor 2.Five Core Copper Conductor 3.Copper Wire Screened Cable 4.Steel Tape Armoured 5.Steel Wire Armoured Cable 6.Construciton Cable
Product Categories : PVC Insulated Power Cable