Huayuan Gaoke Cable Co.,Ltd.
Flexible Flat Cable,Rubber Insulated Cable,For Moving Equipment Power Cable Supplying
Payment Type: | L/C,T/T,D/P |
---|---|
Incoterm: | FOB,CFR,CIF,FCA,CPT,CIP |
Min. Order: | 1000 Meter |
Model No.: YJGCFPB
Brand: HUAYUAN YONGTONG
Type: Insulated
Conductor Type: Stranded
Application: Heating
Conductor Material: Copper
Sheath Material: Crosslinking
Insulation Material: Rubber
Material Shape: Round Wire
Certification: ISO9001
Brand: HUAYUAN YONGTONG
Packaging: DRUMS
Productivity: 100KM/M
Transportation: Ocean,Land
Place of Origin: BEIJING CHINA
Supply Ability: 100KM/M
Certificate: CE,ISO,CCC
HS Code: 8544601200
Port: Tianjin Port,Shanghai Port,Qingdao Port
Payment Type: L/C,T/T,D/P
Incoterm: FOB,CFR,CIF,FCA,CPT,CIP
YJGCFPB-10KV power high-voltage flat cable
Use performance
1 11. Rated voltage:6/10KV.
12. Maximum operating temperature:180℃.
3.Minimum temperature:-35℃.
Insulation
1. Material quality: three EPDM insulation
2. 2.Tensile strength:≥5N/mm2.
3.Elongation at break≥150%.
Sheath
1. Material quality: Chloride butyl mixed sheath material
2. Tensile strength:≥8N/mm2.
3. Elongation at break≥150%.
AC withstand voltage test frequency 50HZ AC 15KV/5minutes No breakdown
Cable parameter report
Flat cable Model Specifications 3*35 mm2 Rated voltage 10000 V Inspection standard Q/HL022-2008
Test item | unit | standard value | measured value | |
1.Structure | 1.1 Cross section | mm2 | 35 | 35 |
1.2 Average thickness of insulation ≥ | mm | 6 | 6 | |
The most thin thickness≥ | mm |
|
| |
1.3 Sheath average thickness≥ | mm | 3.2 | 3.2 | |
The most thin thickness≥ | mm |
|
| |
1.4 Shielding density≥ | % | 80 | 80 | |
1.5 Aluminum foil coverage rate | % | / | / | |
1.6 Copper coverage rate | % | / | / | |
2.DC conductor resistance.(20℃)≤ | Ω/km | 0.565 | 0.565 | |
3.Cable AC withstand test | 15 Kv/ 5minutes No breakdown | No breakdown | ||
4.Appearance | Smooth, no particles | Smooth, no particles | ||
5.Cable print marking | Clear handwriting | Clear handwriting | ||
Inspecion results: the inspection accord with Q/HL022-2008 require, the cable is qualified product. |
Model | Number of cores × Nominal cross section (mm 2) | Conductor structure | Average Dimensions (mm) | 20 ° C conductor shape resistance ≤ (Ω / km) | Reference weight (kg / km) | |
Copper core | Tinned copper | |||||
YJGCFPB-10KV | 3 × 16 +3 × 16/3 | 126/0.04 | (70-75) × (31-33) | 1.21 | 1.24 | 3700 |
3 × 25 +3 × 16/3 | 196/0.40 | (76-81) × (33-35) | 0.780 | 0.795 | 4300 | |
3 × 35 +3 × 16/3 | 276/0.40 | (79-84) × (34-36) | 0.554 | 0.565 | 4800 | |
YJGCFPB-6KV | 3 × 16 +3 × 16/3 | 126/0.04 | (62-64) × (27-28) | 1.21 | 1.24 | 2815 |
3 × 25 +3 × 16/3 | 196/0.40 | (66-69) × (29-31) | 0.780 | 0.795 | 4100 | |
3 × 35 +3 × 16/3 | 276/0.40 | (70-73) × (30-33) | 0.554 | 0.565 | 4750 | |
3 × 50 +3 × 16/3 | 396/0.40 | (76-79) × (32-35) | 0.386 | 0.393 | 6300 | |
3 × 70 +3 × 25/3 | 360/0.50 | (82-85) × (34-37) | 0.272 | 0.277 | 7380 | |
3 × 95 +3 × 35/3 | 475/0.50 | (88-92) × (36-39) | 0.206 | 0.210 | 7800 | |
3 × 120 +3 × 35/3 | 608/0.50 | (96.5-100) × (39-41) | 0.161 | 0.164 | 9500 |
Product Categories : Rubber Power Cable