Huayuan Gaoke Cable Co.,Ltd.
Aluminum Wire Armour Steel Tape For Cable,36kv Copper Screen XLPE Insulation Cable,N2XSY N2XSEY NA2XSY NA2XSEY N2XSRY NA2XSRY N2XSEBY Cable
Payment Type: | L/C,T/T,D/P,Western Union |
---|---|
Incoterm: | FOB,CFR,CIF,FCA,CPT |
Min. Order: | 1000 Meter |
Model No.: N2XSEY
Brand: HUAYUAN YONGTONG
Type: Insulated
Conductor Type: Stranded
Application: Underground
Conductor Material: Copper
Sheath Material: PVC
Insulation Material: XLPE
Material Shape: Round Wire
Range of Application: LSOH
Certification: ISO9001
Brand: HUAYUAN YONGTONG
Packaging: Drums
Productivity: 100KM/M
Transportation: Ocean,Land,Air
Place of Origin: BEIJING CHINA
Supply Ability: 100KM/M
Certificate: CE ISO CCC
HS Code: 8544601300
Port: Tianjin Port,Shanghai Poer,Qingdao Port
Payment Type: L/C,T/T,D/P,Western Union
Incoterm: FOB,CFR,CIF,FCA,CPT
TECHNICLA DATA SHEET FOR 36 kV 1C240 SQmm POWER CABLE
NO. ITEM UNIT DATA
1 Name of Manufacturer: Beijing Huayuan Gaoke Cable Co.,Ltd.
2 Country of Manufacturer: China
3 Which type of manufacturing process viz. Continuous Catanery Vulcanisation (CCV) or vertical Catanery Vulcanisation system (VCV) or horizontal MDCV will be used to ensure circularity and concentricity of the extruded layers around the conductor. CCV
4 Type of Cable: Cu/XLPE/AWA/PVC
5 Rated nominal voltage kV 18/30
6 Rated Maximum voltage kV 36
7 Nominal cross-sectional area of Conductor Sq.mm 240
8 Conductor
8.1 Material Copper
8.2 Shape & formation Round
8.3 Diameter of conductor mm 18.4
8.4 Dia.Of Single Wire/Number of strands mm 2.98/60
9 Conductor Screen
9.1 Material semi conductive XLPE
9.2 Thickness of semi-conductor screen mm 0.8
9.3 Diameter of Semi-conductor(Approx.) mm 20
10 Insulation
10.1 Material XLPE
10.2 Insulation Thickness(Min.Avg.) mm 8
10.3 Diameter of Insulation(Approx.) mm 36
11 Insulation Screen
11.1 Material Semi-conductive material
11.2 Insulation Screen Thickness(Approx.) mm 0.8
11.3 Diameter of Sime-Insulation(Approx.) mm 37.6
12 Metallic Screen:
12.1 Material Copper tape
12.2 Thickness of the copper tape screen mm 0.12
12.3 Diameter of the cable across the metallic screen(Approx.) mm 38
13 Inner sheath
13.1 Material PVC
13.2 Approximate thickness mm 1.3
13.3 Diameter of inner sheath (Approx.) mm 40.6
14 Armouring
14.1 Material Aluminum wire+ nonmagnetic steel tape
14.2 Approximate diameter / thickness mm/mm 2.5/0.3
14.3 Diameter of armouring (Approx.) mm 46.2
15 Outer Sheath
15.1 Material PVC
15.2 Outer Sheath Thickness(Nominal) 2.6
15.3 Over Diameter(Approx.) 51.4
16 Conductor Weight kg/km 2136
16.1 Total Cable Weight (Approx.) kg/km 4900
17 Minimum Bending Radius
17.1 During Installation mm 800
17.2 Installed mm 650
18 Maximum Pulling Tension
18.1 Of Conductor kN 16.8
19 Continuous current rating under the specified installation and operating conditions. Conductor temperature 90° C . Ground temperature 35° C and depth of laying 1500 mm
19.1 In Air Amp 415
19.2 In Ground Amp 326
19.3 In pipeline Amp 302
20 Maximum value of electric stresses at the conductor screen (Calculation to be shown separately) kV/mm 3.06
21 Maximum value of dielectric stress at the insulation kV/mm 1.7
22 Short circuit capacity of conductor for 1/2/3 second assuming conductor temperature of 90 ° C prior to short circuit and 250 ° C during short circuit
22.1 1.0 Secs kA 34.4
22.2 2.0 Secs kA 24.5
22.3 3.0 Secs kA 20
23 Short circuit capacity of metallic screen for 1/2/3 second at screen temperature of 80 ° C prior to short circuit and 200 ° C during short circuit
23.1 1.0 Secs kA 2.3
23.2 2.0 Secs kA 1.5
23.3 3.0 Secs kA 1.3
24 Screen voltage under maximum operating conditions assuming all circuits connected kV per km 0.05
25 TEST
25.1 Maximum D.C. resistance of conductor per km. at 20 degree C. Ohm 0.0754
25.2 Maximum A.C. resistance of conductor per km. at 90 degree C. Ohm 0.097
25.3 Maximum electrostatic capacitance per km. of cable. μF 0.218
25.4 Partial discharge at 1.50 Uo pc ≤ 10
25.5 A.C. Enduring Test voltage 2.5U0/ hours kV/mim 63/3 Not breakdown
25.6 D.C.Out sheath Enduring Test voltage kV/mim 5kV/1min
25.7 Impulse test voltage kV 120
26 Approximate drum dimension (dia & width) mm/mm 2200*1400
27 Maximum length of cable in a drum (Metres) m 600
28 Minimum length of cable in a drum (Metres) m 550
39 Approximate gross weight of cable in a drum TON 3
30 Expected Cable life. Year 30
Drawing of Configuration
Cu/LPE/AWA/PVC 18/30 (36) kV 1×240mm2
Construction | Thickness(mm) | Diameter(mm) |
1 --- Copper Conductor |
| 18.4(+0.1,-0.1) |
2 --- Conductor screen | 0.8 | 20.0 |
3 --- XLPE insulation | 8.0 | 36.0(+0.5,-0.5) |
4 --- Insulation screen | 0.8 | 37.6 |
5 --- Copper tape screen | 0.12 | 38.0 |
6 --- PVC inner sheath | 1.3 | 40.6(+1.5,-1.5) |
7 --- Aluminum wire armor+steel tape | 2.5+0.3 | 46.2 |
8 --- PVC outer sheath | 2.6 | 51.4(+2.5,-2.0) |
Advanced Manufacturing Equipments
Advanced Testing Equipments
The company introduced the world's advanced level wire & cable production and testing equipment, such as DV-6E spectrum analyzer, online micro pore impurity tester, etc.
Advanced Testing Equipment Guarantee High Quality Production
1.High Voltage Power Cable 2.Three Core Aluminium Conductor 3.Single Core Aluminium Conductor 4.Aluminium Corrugated Cable 5.Four Core Aluminium Conductor 6.High Quality Aluminum Alloy
Product Categories : Copper Conductor Power Cable