http://www.bjhygkcable.com
Home > Products > Electrical Wire Cable > Power 600 Volts XHHW 2 Cable UL Cable Low Voltage Copper Building Wire

Power 600 Volts XHHW 2 Cable UL Cable Low Voltage Copper Building Wire

    Payment Type: L/C,T/T,D/P,Paypal,Money Gram,Western Union
    Incoterm: FOB,CFR,CIF,FCA,CPT
    Min. Order: 100 Meter
Basic Info

Model No.XHH2

BrandHUYUAN YONGTONG

TypeInsulated

ApplicationHeating

Conductor MaterialCopper

Sheath MaterialCrosslinking

Insulation MaterialXLPE

Material ShapeRound Wire

Range of ApplicationLSOH

CertificationCCC

BrandHUAYUAN YONGTONG

Additional Info

PackagingCOIL

Productivity500KM/MONTH

TransportationOcean,Land,Air

Place of OriginBEIJING CHINA

Supply Ability500KM/MONTH

CertificateCE,CCC,ISO

HS Code8544601200

PortShanghai Port,Tianjin Port,Qingdao Port

Payment TypeL/C,T/T,D/P,Paypal,Money Gram,Western Union

IncotermFOB,CFR,CIF,FCA,CPT

Product Description

Product Description:

 COPPER Building Wire CABLE

CONSTRUCTION
 

 

 

 

 
STANDARD
 
ASTM,UL 44
 

 

 
VOLTAGE
 

 
600V
 

 

 

 
CONDUCTOR
 
soft annealed copper.#14-4/0AWGuses a compressed copper strand.
INSULATION
 
Cross-Linked Polyethylene (XLP) Insulation.
 
XHHW-2 copper conductors are annealed (soft) copper. Insulation is an
abrasion, moisture, and heat resistant thermoset cross-linked polyethylene (XLP). Conductor sizes 8
AWG and larger are marked sunlight resistant. Colors are available and may be subject to economic
order quantity.
APPLICATION
 

 

 

 

 

 
XHHW-2 conductors are primarily used in conduit,Cable Tray or other recognized raceways for service's, feeders, and branch circuit wiring,as specified in the National Electrical Code.XHHW-2 conductors may be used in wet or dry locations at temperatures not to exceed 90° C. Voltage rating for XHHW-2 conductors is 600volts.Suitable for use in Health Care Facilities per Section 517.160 of the National Electrical Code where a dielectric constant of less than 3.5 maybe specified. This cable is designed to be installed without the application of pulling lubricant.
CABLE  CONSTRUCTION

 

 

 

 

 

 

 

 
Conductor Insulation Max. DC 
Resistance at 20°C
Approx.weight
(AWG or kcmil) No of strands Thickness(mils)  Diameter(mils) Ohm/km 1000' (lbs)
14* 7 30 130 8.79 18
12* 1 30 141 5.41 24
10* 1 30 147 3.64 26
12* 7 30 162 9.10 37
10* 7 30 171 5.60 40
8 7 45 232 2.36 65
6 7 45 268 1.44 96
4 7 45 311 0.91 147
3 7 45 337 0.71 183
2 7 45 367 0.57 227
1 19 55 435 0.47 291
2/0 19 55 521 0.29 453
4/0 19 55 627 0.18 706

Power-600-Volts-XHHW-2-Cable-UL-Cable-Low-Voltage-Copper-Building-WirePower-600-Volts-XHHW-2-Cable-UL-Cable-Low-Voltage-Copper-Building-Wire (2)



1.Building Wire  2.Low Voltage Power Cable  3.0.6kv Cable  4.1kv Cable  5.PVC Flexible Control Cable

Product Categories : Electrical Wire Cable

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Crazy Zhang Mr. Crazy Zhang
What can I do for you?
Contact Supplier