Huayuan Gaoke Cable Co.,Ltd.
XLPE Insulated High Voltage Cable,For Instruments/ignition Systems Cable,For Power Transmission Lines Cable
Payment Type: | L/C,T/T,D/P |
---|---|
Incoterm: | FOB,CFR,CIF,FCA,CPT |
Min. Order: | 1000 Meter |
Model No.: YJV
Brand: HUAYUAN YONGTONG
Type: Insulated
Conductor Type: Stranded
Application: Underground
Conductor Material: Copper
Sheath Material: Crosslinking
Insulation Material: XLPE
Material Shape: Round Wire
Range of Application: LSOH
Certification: ISO9001
Packaging: DRUMS
Productivity: 100KM/M
Transportation: Ocean,Land
Place of Origin: BEIJING, CHINA
Supply Ability: 100KM/M
Certificate: CE,ISO,CCC
HS Code: 8544601400
Port: Tianjin Port,Shanghai Port,Qingdao Port
Payment Type: L/C,T/T,D/P
Incoterm: FOB,CFR,CIF,FCA,CPT
A high-voltage cable (HV cable) is a cable used for electric power transmission at high voltage. A cable includes a conductor and insulation, and is suitable for being run underground or underwater. This is in contrast to a conductor, which does not have insulation. High-voltage cables of differing types have a variety of applications in instruments, ignition systems, and AC and DC power transmission. In all applications, the insulation of the cable must not deteriorate due to the high-voltage stress, ozone produced by electric discharges in air, or tracking. The cable system must prevent contact of the high-voltage conductor with other objects or persons, and must contain and control leakage current. Cable joints and terminals must be designed to control the high-voltage stress to prevent breakdown of the insulation. Often a high-voltage cable will have a metallic shield layer over the insulation, connected to the ground and designed to equalize the dielectric stress on the insulation layer.
1)IEC 60060:2010 High Voltage Testing Technology;
2)IEC 60228:2004 Insulated Cable Conductor;
3)IEC 60229:2007 Test on Extruded Cable Sheath with Special Protective Function;
4)IEC 60230:1966 Impact Test on Cable and Cable Accessories;
5)IEC 60071:2006 Insulation Co-ordination;
6)IEC 60287:2006 Rated Continuous Current Calculation of Cable;
7)IEC 60811:2001 Non-electrical Test & Material Test;
8)IEC 60859:1999 Jointing of Cable and GIS with Rated Voltage of 72.5kV and Above;
9)IEC 60949:2008 calculation of permissible short circuit thermal stability current considering the effect of non- insulated heat;
10)IEC 60885:1988 Electrical Test Methods for Power Cable;
11)IEC 60183:1990 High Voltage Cable Select Guide;
IEC 62067:2006 Extruded Insulated Power Cable
12)Test Method and Requirement with Rated Voltage of 150kV(Um=170kV) to 500kV (Um=550kV);
13)IEC60840:2004 Extruded Insulated Power Cable
Test Method and Requirement with Rated Voltage of 30kV(Um=36kV) to 150kV (Um=170kV).
Meanwhile, our company can also manufacture cable products according to other standards such as ASTM, AS and BS Standard.
U0/U(Um) (kV) | Nominal System Voltage (kV) | Maximum Working Voltage (kV) | Lightning Impulse Withstand Voltage (kV) | Switching Impulse Withstand Voltage (kV) |
38/66(72.5) | 66 | 72.5 | 342 | |
48/66(72.5) | 66 | 72.5 | 342 | |
64/110(126) | 110 | 126 | 550 | |
76/132(145) | 132 | 145 | 640 | |
127/220(252) | 220 | 252 | 1050 | |
160/275(300) | 275 | 300 | 1050 | 850 |
190/330(362) | 330 | 362 | 1175 | 950 |
220/400(420) | 400 | 420 | 1425 | 1050 |
290/500(550) | 500 | 550 | 1550 (Peak Value) | 1175 (Peak Value) |
1.High Voltage Power Cable 2.HV XLPE Cable 3.132kv Cable 4.Electrical Cbale Wires 5.Construction Cable 6.High Quality 3 Core Power Cable
Product Categories : High Voltage Power Cable