http://www.bjhygkcable.com
Home > Products > High Voltage Power Cable > 132kV 2000mm2 XLPE High Tension Power Cable

132kV 2000mm2 XLPE High Tension Power Cable

    Payment Type: L/C,T/T,D/P
    Incoterm: FOB,CFR,CIF,FCA,CPT
    Min. Order: 1000 Meter
Basic Info

Model No.YJV

BrandHUAYUAN YONGTONG

TypeInsulated

Conductor TypeStranded

ApplicationUnderground

Conductor MaterialCopper

Sheath MaterialCrosslinking

Insulation MaterialXLPE

Material ShapeRound Wire

Range of ApplicationLSOH

CertificationISO9001

Additional Info

PackagingDRUMS

Productivity100KM/M

TransportationOcean,Land

Place of OriginBEIJING, CHINA

Supply Ability100KM/M

CertificateCE,ISO,CCC

HS Code8544601400

PortTianjin Port,Shanghai Port,Qingdao Port

Payment TypeL/C,T/T,D/P

IncotermFOB,CFR,CIF,FCA,CPT

Product Description

A high-voltage cable (HV cable) is a cable used for electric power transmission at high voltage. A cable includes a conductor and insulation, and is suitable for being run underground or underwater. This is in contrast to a conductor, which does not have insulation. High-voltage cables of differing types have a variety of applications in instruments, ignition systems, and AC and DC power transmission. In all applications, the insulation of the cable must not deteriorate due to the high-voltage stress, ozone produced by electric discharges in air, or tracking. The cable system must prevent contact of the high-voltage conductor with other objects or persons, and must contain and control leakage current. Cable joints and terminals must be designed to control the high-voltage stress to prevent breakdown of the insulation. Often a high-voltage cable will have a metallic shield layer over the insulation, connected to the ground and designed to equalize the dielectric stress on the insulation layer.

1)IEC 60060:2010 High Voltage Testing Technology;
2)IEC 60228:2004 Insulated Cable Conductor;
3)IEC 60229:2007 Test on Extruded Cable Sheath with Special Protective Function;
4)IEC 60230:1966 Impact Test on Cable and Cable Accessories;
5)IEC 60071:2006 Insulation Co-ordination;
6)IEC 60287:2006 Rated Continuous Current Calculation of Cable;
7)IEC 60811:2001 Non-electrical Test & Material Test;
8)IEC 60859:1999 Jointing of Cable and GIS with Rated Voltage of 72.5kV and Above;
9)IEC 60949:2008 calculation of permissible short circuit thermal stability current considering the effect of non-         insulated heat;
10)IEC 60885:1988 Electrical Test Methods for Power Cable;
11)IEC 60183:1990 High Voltage Cable Select Guide;
      IEC 62067:2006 Extruded Insulated Power Cable
12)Test Method and Requirement with Rated Voltage of 150kV(Um=170kV) to 500kV (Um=550kV);
13)IEC60840:2004 Extruded Insulated Power Cable
      Test Method and Requirement with Rated Voltage of 30kV(Um=36kV) to 150kV (Um=170kV).

Meanwhile, our company can also manufacture cable products according to other standards such as ASTM, AS and BS Standard.

U0/U(Um)
(kV)
Nominal System Voltage (kV)
Maximum Working
Voltage (kV)
Lightning Impulse
Withstand Voltage (kV)
Switching Impulse
Withstand Voltage (kV)
38/66(72.5)
66
72.5
342

48/66(72.5)
66
72.5
342

64/110(126)
110
126
550

76/132(145)
132
145
640

127/220(252)
220
252
1050

160/275(300)
275
300
1050
850
190/330(362)
330
362
1175
950
220/400(420)
400
420
1425
1050
290/500(550)
500
550
1550 (Peak Value)
1175 (Peak Value)
132kv XLPE Power Cable PE and PVC Outer Sheath Uhv Cable

110kv out door terminations and lightening arresters
  
 220kv cable processed for cable accessories installations

132KV CABLE WITHNESSED BY SGS DELELGATES IN SEA PORT BEFORE LOADING IN CONTAINERS

220KV CABLE MIDDLE JOINTS

132KV CABLE AND ACCESSORIES INSTALLATION

132KV CABLE ACCESSOREIS INSTALLATION


 

foreign customers in our factory

HV XLPE INSULATED UNDERGROUND CABLE

Transtation Way



1.High Voltage Power Cable  2.HV XLPE Cable  3.132kv Cable  4.Electrical Cbale Wires  5.Construction Cable  6.High Quality 3 Core Power Cable

Product Categories : High Voltage Power Cable

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Crazy Zhang Mr. Crazy Zhang
What can I do for you?
Contact Supplier