Huayuan Gaoke Cable Co.,Ltd.
Copper Wire Armouring Cable,PVC Outer Sheath for Cable,Plain Annealed Copper Tape Metallic Screen for Cable
Payment Type: | L/C,T/T,D/P,Paypal,Western Union |
---|---|
Incoterm: | FOB,CFR,CIF,FCA,CPT |
Min. Order: | 500 Meter |
Model No.: YJV
Brand: HUAYUAN YONGTONG
Application: Construction
Voltage: Low and Medium Voltage Cable
Current: AC Cable
Insulation Material: XLPE
Sheath Material: PVC
Material Shape: Round Wire
Wire Core Material: Bare Copper Wire
Certification: ISO
Brand: HUAYUAN YONGTONG
Packaging: Drums
Productivity: 100KM/M
Transportation: Ocean,Land,Air
Place of Origin: BEIJING,CHINA
Supply Ability: 100KM/M
Certificate: CE,CCC,ISO
HS Code: 8544601300
Port: Tianjin Port,Shanghai Port,Qingdao Port
Payment Type: L/C,T/T,D/P,Paypal,Western Union
Incoterm: FOB,CFR,CIF,FCA,CPT
TECHNICLA DATA SHEET FOR 36 kV 3C 120 SQmm POWER CABLE
NO. ITEM UNIT DATA 1 Name of Manufacturer: Beijing Huayuan Gaoke Cable Co.,Ltd. 1.2 Country of Manufacturer: China 2 Which type of manufacturing process viz. Continuous Catanery Vulcanisation (CCV) or vertical Catanery Vulcanisation system (VCV) or horizontal MDCV will be used to ensure circularity and concentricity of the extruded layers around the conductor. CCV 3 Type of Cable: Cu/XLPE/AWA/PVC 4 Rated nominal voltage kV 20/36 5 Rated Maximum voltage kV 36 6 Nominal cross-sectional area of Conductor Sq.mm 120 7 Conductor 7.1 Material Copper 7.2 Shape & formation Round 7.3 Diameter of conductor mm 13 7.4 Dia.Of Single Wire/Number of strands mm 2.78/19 8 Conductor Screen 8.1 Material semi conductive material 8.2 Thickness of semi-conductor screen mm 0.8 8.3 Diameter of Semi-conductor(Approx.) mm 14.6 9 Insulation 9.1 Material XLPE 9.2 Insulation Thickness(Min.Avg.) mm 8 9.3 Diameter of Insulation(Approx.) mm 30.6 10 Insulation Screen 10.1 Material Semi-conductive material 10.2 Insulation Screen Thickness(Approx.) mm 1 10.3 Diameter of Sime-Insulation(Approx.) mm 32.2 11 Metallic Screen: 11.1 Material Plain Annealed Copper Tape 11.2 Thickness of the copper tape screen mm 0.1 11.3 Diameter of the cable across the metallic screen(Approx.) mm 32.5 12 Filler 12.1 Material Non-hygroscopic Filler 12.2 Diameter of Laid-Up Core 70.2 13 Bedding tape 13.1 Material Nonwoven tape 13.2 Approximate thickness mm 0.2 13.3 Diameter over of bedding (Approx.) mm 71.4 14 Inner Sheath 14.1 Material PVC 14.2 Inner Sheath Thickness(Nominal) 2 14.3 Diameter over the Inner sheath(Approx.) 75.4 15 Armouring 15.1 Material Steel tape 15.2 Approximate diameter or thickness mm/ 0.8 15.3 Diameter of armouring (Approx.) mm 78.6 16 Outer Sheath 16.1 Material PVC 16.2 Outer Sheath Thickness(Nominal) 3.7 16.3 Over Diameter(Approx.) 86 17 Conductor Weight kg/km 3.141 17.1 Total Cable Weight (Approx.) kg/km 10790 18 Minimum Bending Radius 18.1 During Installation mm 1750 18.2 Installed mm 1500 19 Maximum Pulling Tension 19.1 Of Conductor kN 25.2 20 Continuous current rating under the specified installation and operating conditions. Conductor temperature 90° C . Ground temperature 25° C and depth of laying 1000 mm 20.2 In Ground Amp 335 21 Maximum value of electric stresses at the conductor screen (Calculation to be shown separately) kV/mm 3.7 21.1 Maximum value of dielectric stress at the insulation kV/mm 1.77 22 Short circuit capacity of conductor for 1/2/3 second assuming conductor temperature of 90 ° C prior to short circuit and 250 ° C during short circuit 22.1 1.0 Secs kA 17.2 22.2 2.0 Secs kA 12.2 22.3 3.0 Secs kA 10.1 23 Short circuit capacity of metallic screen for 1/2/3 second at screen temperature of 80 ° C prior to short circuit and 200 ° C during short circuit 23.1 1.0 Secs kA 6.2 23.2 2.0 Secs kA 4.3 23.3 3.0 Secs kA 3.8 24 Screen voltage under maximum operating conditions assuming all circuits connected kV per km 0.05 25 TEST 25.1 Maximum D.C. resistance of conductor per km. at 20 degree C. Ohm 0.153 25.2 Maximum A.C. resistance of conductor per km. at 90 degree C. Ohm 0.196 25.3 Maximum electrostatic capacitance per km. of cable. μF 0.174 25.4 Partial discharge at 1.50 Uo pc ≤ 10 25.5 A.C. Enduring Test voltage 2.5U0/ hours kV/mim May-70 25.6 D.C.Out sheath Enduring Test voltage kV/mim 5kV/1min 25.7 Impulse test voltage kV 170 26 Approximate drum dimension (dia & width) mm/mm 2800*1700 27 Maximum length of cable in a drum (Metres) m 600 28 Minimum length of cable in a drum (Metres) m 500 39 Approximate gross weight of cable in a drum TON 5.8 30 Expected Cable life. Year 30
Drawing of Configuration
Cu/LPE/AWA/PVC 18/30 (36) kV 3×150mm2
Construction | Thickness(mm) | Diameter(mm) |
1 --- Copper Conductor |
| 13.0(+0.1,-0.1) |
2 --- Conductor screen | 0.8 | 14.6 |
3 --- XLPE insulation | 8.0 | 30.6(+0.5,-0.5) |
4 --- Insulation screen | 0.8 | 32.2 |
5 --- Copper tape screen | 0.1 | 32.5 |
6 --- PP filler |
| 70.2 |
7 --- Non-woven fabrics tape | 0.2 | 71.4 |
8 --- PVC inner sheath | 2.0 | 75.4(+1.5,-1.5) |
9 --- Aluminum wire armor+steel tape | 3.15+0.3 | 82.3 |
10--- PVC outer sheath | 3.8 | 89.9(+2.5,-2.0) |
Advanced Manufacturing Equipments
Advanced Testing Equipments
The company introduced the world's advanced level wire & cable production and testing equipment, such as DV-6E spectrum analyzer, online micro pore impurity tester, etc.
Advanced Testing Equipment Guarantee High Quality Production
1.Middle Voltage Power Cable 2.Steel Wire Armoured Cable 3.Steel Tape Armoured 4.Three Core Aluminium Conductor 5.Aluminium Corrugated Cable 6.Four Core Aluminium Conductor 7.PVC Flexible Control Cable
Product Categories : Middle Voltage Power Cable