    Min. Order: 1000 Meter
Basic Info

Model No.YJLV

BrandHUYUAN YONGTONG

TypeInsulated

Conductor TypeStranded

ApplicationUnderground

Conductor MaterialAluminum

Sheath MaterialCrosslinking

Insulation MaterialXLPE

Material ShapeRound Wire

Range of ApplicationLSOH

CertificationISO9001

BrandHUAYUAN YONGTONG

Additional Info

PackagingDRUM

Productivity100KM/MONTH

TransportationOcean,Land,Air

Place of OriginCHINA

Supply Ability100KM/MONTH

CertificateCE,CCC,ISO

HS Code8544601200

PortShanghai Port,Tianjin Port,Qingdao Port

Payment TypeL/C,T/T,D/P,Western Union

IncotermFOB,CFR,CIF,FCA,CPT,CIP

Product Description

Middle Voltage 20kv Aluminum Conductor XLPE Insulated Power Cable
1. Description
Construction: Compacted stranded circular aluminum conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC or PE outer sheath.

2. Operating Characteristics
Rated voltage U0/U(Um): 12/20(24)kV
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the "highest system voltage" for which the equipment may be used.
Max. Permissible continuous operating temperature of conductor: 90 ° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed: 250 ° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 20 times of the diameter of cable
For three core cable: Not less than 15 times of the diameter of cable

 
Size
Nominal thickness of XLPE insulation(mm) Approx. thickness of copper tape screen (mm) Nominal thickness of PVC or PE(mm) Approx. overall diameter of finished cable(mm) Max. conductor D.C resistance @ 20ºC(Ω/km)
3x35mm 2 5.5 0.10 2.6 53.5 0.868
3x50mm 2 5.5 0.10 2.7 56.1 0.641
3x70mm 2 5.5 0.10 2.8 61.0 0.443
3x95mm 2 5.5 0.10 2.9 63.8 0.320
3x120mm 2 5.5 0.10 3.0 67.0 0.253
3x150mm 2 5.5 0.10 3.1 70.7 0.206
3x185mm 2 5.5 0.10 3.3 74.7 0.164
3x240mm 2 5.5 0.10 3.4 80.1 0.125
3x300mm 2 5.5 0.10 3.6 84.9 0.100
3x400mm 2 5.5 0.10 3.8 92.4 0.0778
steel wire and Aluminium Wire armouring machine 2

Stee wire and Aluminium Wire armouring Machine

91 DRUMS COPPER WIRES STRANDING LINES

XLPE-Insulated-Armoured-PVC-Sheathed-Power-Cable (1)

Loaded in the Container for Shipment

middle voltage package1


company instruction

Product Categories : Middle Voltage Power Cable

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Crazy Zhang Mr. Crazy Zhang
What can I do for you?
Contact Supplier