http://www.bjhygkcable.com
Home > Products > Middle Voltage Power Cable > MV Underground 12/20 (24) KV XLPE Insulated Cable

MV Underground 12/20 (24) KV XLPE Insulated Cable

    Payment Type: L/C,T/T,D/P,Western Union
    Incoterm: FOB,CFR,CIF,FCA,CPT
    Min. Order: 1000 Meter
Basic Info

Model No.N2XSRY

BrandHUAYUAN YONGTONG

TypeInsulated

Conductor TypeStranded

ApplicationUnderground

Conductor MaterialCopper

Sheath MaterialCrosslinking

Insulation MaterialXLPE

Material ShapeRound Wire

Range of ApplicationLSOH

CertificationISO9001

BrandHUAYUAN YONGTONG

Additional Info

PackagingDRUMS

Productivity500kilometers/month

TransportationOcean,Land,Air

Place of OriginBeijing, China

Supply Ability500kilometers/month

CertificateCE,CCC,ISO

HS Code8544601200

PortTianjin Port,Shanghai Port,Qingdao Port

Payment TypeL/C,T/T,D/P,Western Union

IncotermFOB,CFR,CIF,FCA,CPT

Product Description

MV Underground 12/20 (24) KV XLPE Insulated Cable


Application: The MV Underground 12/20 (24) KV XLPE Insulated Cable is suitable to be installed in transmission and distribution lines.         

           

Standard: IEC, BS, ASTM, AS/NZS, IS and other standards as customers' required.

 

Characteriestics: 

1)Max. operating temp. of the cable conductor is 90˚C. 

2)Max. short circuit temp. of the cables conductor shall not exceed 250˚C.(max. duration not exceed 5s)
3)There are three kinds of rated voltage (U0) according to the ground fault duration, see the following table.

Type A: when any phrase conductor of this system connected to ground or earthed conductor, it can be separated with the system within 1minute.
Type B: when single phrase grounded of this system,it can run short time. The grounded time should not exceed 1 hour. cables under this system should not run over 8 hours In Soiled fault situation and the total continue fault grounded time of one year should not exceed 125 hours.
Type C: included all systems excluded in A & B. 

4) When laying the cables at the ambient temp. of 0˚C and above, there is no need to pre-heat.

Max. Voltage of System(Um/kV)

Rated Voltage(U0)/kV

 

Type A & B

Type C

7.2

3.6

6.0

12

6.0

8.7

17.5

8.7

12.0

24.0

12.0

18.0

36.0

18.0

-

40.5

21

26

steel wire and Aluminium Wire armouring machine 2


91 DRUMS COPPER WIRES STRANDING LINES

Stee wire and Aluminium Wire armouring Machine

middle voltage

middle voltage package1

Usage

Shipping Method

Certificates

1.Middle Voltage Power Cable  2. MV XLPE Cable  3.Copper Wire Screened Cable  4.Underground Cable  5. 11kv Cable  6. Low Voltage Power Cable

Product Categories : Middle Voltage Power Cable

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Crazy Zhang Mr. Crazy Zhang
What can I do for you?