Huayuan Gaoke Cable Co.,Ltd.
Copper XLPE Insulated Single Core Electric Cable,For Power Plant and Industry the Cable,Cable Use For Tunnel
Payment Type: | L/C,T/T,D/P,Western Union |
---|---|
Incoterm: | FOB,CFR,CIF,FCA,CPT |
Min. Order: | 1000 Meter |
Model No.: YJV
Brand: HUAYUAN YONGTONG
Type: Insulated
Conductor Type: Stranded
Application: Underground
Conductor Material: Copper
Sheath Material: Crosslinking
Insulation Material: XLPE
Material Shape: Round Wire
Range of Application: LSOH
Certification: ISO9001
Brand: HUAYUAN YONGTONG
Packaging: DRUMS
Productivity: 100KM/M
Transportation: Ocean,Land,Air
Place of Origin: BEIJING, CHINA
Supply Ability: 100KM/M
Certificate: CE,ISO,CCC
HS Code: 8544601200
Port: Shanghai Port,Tianjin Port,Qingdao Port
Payment Type: L/C,T/T,D/P,Western Union
Incoterm: FOB,CFR,CIF,FCA,CPT
XLPE insulated 70mm copper cable
1.Has passed CE, ISO, CCC, PCCC...certificate
2.sell well in Europe, America, Asia and Africa.
3. Standard GB, IEC, AS
1.Product standard
GB/T12706-2002 (IEC60502-1983)
Applications
The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6KV/6KV~26/35KV.
Operating characteristics
Rated power-frequency voltage U0/U: 3.6/6KV~26/35KV.
Max. Permissible continuous operating temperature or conductor:90°C.
Max. short-circuit temperature of conductor shall not exceed 250°C. (5s maximum duration)
The ambient temperature under installation should not below 0°C.
The bending radius of a single-core cable should not less than 20 times of the cable diameter.
The bending radius of a three-core cable should not less than 15 times of the cable diameter.
Voltage designation
The rated voltage of the cable for a given application shall be suitable for the operating conditions in the system in which the cable is used, and is expressed in the form of U0/U (Um) KV. Where:
U0-The rated power-frequency voltage between conductor and earth or metallic screen, for which the cable designed;
U-The rated power-frequency voltage between conductors, for which the cable designed;
Um-The maximum value of the [highest system voltage" for which the equipment may be used.
TYPE Number of cores Rated Voltage (U0/U)kV 6/6 6/10 8.7/10 8.7/15 12/20 18/20 21/35 26/35 Nominal cross-section area of conductor mm2 YJV YJV32(42) 1 25~630 25~630 25~400 50~500 YJLV YJLV32(42) 35~630 35~630 35~300 50~630 YJV22 25~500 25~500 35~500 - YJLV22 35~500 35~500 35~500 - YJV YJV22 3 25~300 25~300 35~300 50~300 YJLV YJLV22 35~300 35~300 35~300 50~300 YJV32 YJLV32 25~300 35~300 35~300 50~300 YJV42 YJLV42 35~185 35~185 35~150 50~300