1. GENERAL
This listed specification covers the structure, performance, test and packing information of bare conductor as manufactured by Beijing Huayuan Gaoke Cable Co.,Ltd.
Matters not mentioned in this technical specification shall be negotiated by purchaser & supplier. This document confirms the two parties agreement as technical agreement of contract unless otherwise in official written annexes.
2. APPLICALBE STANDARDS
The cable which TBEA offered shall be designed, manufactured and tested according to international standards as follows:
Quality Control Standard | |
ISO 9001 | Quality Management Systems |
ISO 14001 | Environmental Management Systems |
Applicable Standard | |
ASTM B399 | Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201-T81 Conductors |
3. CONDUCTOR STRUCTURE FOR AAAC
AAACCAIRO 465.4 MCM (235.8mm2)
Construction | Nominal NO./Diameter(mm) | Nominal Diameter(mm) |
1--- Aluminum Alloy Wire | 19 / 3.98 | 19.9 |
4. Guaranteed Technical Particulars
ITEM | DESCRIPTION | UNIT | DATA |
1 | Manufacturer |
| BEIJING HUAYUAN |
2 | Type |
| AAAC CAIRO 465.4 MCM |
3 | Standard |
| ASTM B 399 |
4 | Aluminum Alloy wire |
|
|
a | NO./Nominal diameter of Aluminum Alloy wire | mm | 19/3.98 |
b | Tolerance of Aluminum Alloy wire diameter | mm | ± 1% |
c | Mass of Aluminum Alloy wire(Approximately) | kg/km | 651 |
5 | Completed conductor |
|
|
a | Direction of lay of the outmost layer of stranded conductor | / | Right-hand |
b | Rated Strength | kg | 5352 |
c | Total cross section of conductor | mm2 | 235.8(nominal) |
d | Nominal diameter of conductor | mm | 19.9 |
e | DC Electrical resistance at 20℃ | Ω/km | ≤0.1494 |
f | Mass of completed conductor(Approximately) | kg/km | 651 |
g | Electrical resistivity requirements at 20 ℃ | %ICAS | 52.5 |
h | Rated strength | kN | 69.6 |
h | Linear expanding coefficient | 1/℃ | 23×10-6 |
j | Current rating (30℃ ambient temperature) | A | 565(wind speed 0.5m/s, conductor temp. 80℃, sunlight 1000W/mm2, radiation coefficient 0.6, surface absorption coefficient0.5) |
6 | Test requirements for AAAC conductor, accordance with ASTM standards. |