http://www.bjhygkcable.com
Home > Products > Overhead Cable > TACSR 410mm2 Conductor

TACSR 410mm2 Conductor

    Payment Type: L/C,T/T,D/P,Paypal,Money Gram,Western Union
    Incoterm: FOB,CFR,CIF,FCA,CPT,CIP
    Min. Order: 1000 Kilometer
Basic Info

Model No.TACSR

BrandHUAYUAN YONGTONG

TypeBare

Conductor TypeStranded

ApplicationOverhead

Conductor MaterialAluminum

Insulation MaterialBare

Material ShapeRound Wire

CertificationISO9001

BrandHUAYUAN YONGTONG

Additional Info

PackagingDrum

Productivity1000km/M

TransportationOcean,Land,Air

Place of OriginBeijing,China

Supply Ability1000km/M

CertificateCE,CCC,ISO

PortTianjin Port,Shanghai Port,Qingdao Port

Payment TypeL/C,T/T,D/P,Paypal,Money Gram,Western Union

IncotermFOB,CFR,CIF,FCA,CPT,CIP

Product Description

Specification:

B.1 Technical Requirements

 

 

B.1.1 Technical Characteristics and Requirements

 

 

 

Owner's Requirement

Offered

a) Type

410 mm2 TACSR

410 mm2 TACSR

b) Code Word

N/A

N/A

c) Calculated total cross-sectional area, mm2

480.80 (approx.)

480.80 (approx.)

d) Outer Layers

 

 

1.Material

 Thermal Aluminum Zirconium Alloy (Al-Zir)

Thermal Aluminum Zirconium Alloy (Al-Zir)

2.Calculated Cross-sectional Area, mm2

413.40 (approx.)

413.40 (approx.)

3.Stranding No./dia. No./mm

26/4.5

26/4.5

4.Coefficient of Elongation (1°C) 1

 

23 × 10-6

e) Core

 

 

1.Material

Al. Clad Steel (AS)

Al. Clad Steel (AS)

2.Calculated Cross-sectional Area, (mm2)1

 

 

3.Stranding, No./Dia. No./mm

7/3.5

7/3.5

4.Zinc coating (Class/g/m2)

N/A

N/A

5.Coeff. Of Elongation (/°C) 1

 

13.0× 10-6

f) Conductor Overall Diameter, mm.

28.50 (approx.)

28.50 (approx.)

g) Rated Tensile Strength (RTS), kg

Not less than 13,910

 13910

h) Rated DC Resistance at 20°C, ohm/km 1

 

0.0694

i) Initial Modulus of Elasticity, (kg/mm2 )1

 

7700

j) Final Modulus of Elasticity, (kg/mm2) 1

 

7700

k) Percent Elongation at Rated Strength, % 1

 

 /

I) Permanent Elongation due to 10 year creep at 20% RTS 1

 

 /

m) Conductor Coeff. Of Linear Expansion (/°C) 1

 

18.9×10-6

B.1.2 Other Technical Requirements

 

 

a)Conductor lay, (Right, Left)

Right

Right

b)Length of Lay (Outer Layer) mm. 1

 

285--399(outside)

c)Corrosion Inhibitor (Grease) Required? (Yes, No)

No

No

d)Weight of Conductor (kg/km) 1

 

1587(approx)

e)Length Per Reel, m. 1

 

2000

B.1.3 Cable Reel

 

 

a) Material

Wooden2

Wooden drums with steel reinforced

b) Returnable, (Yes, No)

No

No

c) If yes, return within no. of months after installation

N/A

N/A

B.2 Tests and Experience Requirements

 

 

B.2.1 Test Requirements

 

 

 

Owner's Requirement

Offered

a) Stress-Strain Test and Report Required

Yes5

yes

b) Breaking Strength Test and Reports Required:

Yes6

yes

c)Factory Acceptance Tests (Routine Tests) to be witnessed by Owner's personnel.

No

No

d) Required no. of Owner's personnel to witness test

N/A

N/A 

Conductor construction:

Construction picture1

TACSR/AS 410 mm2

Construction

Nominal NO./Diameter(mm)

Nominal Diameter(mm)

1--- Aluminum-Clad Steel Wire

7 / 3.50

10.50

2--- Aluminum Alloy Wire

26 / 4.50

28.50

 

Standard : IEC 61089 ; Aluminum-Clad Steel Wire standard : IEC 61232 20SA  

Aluminum Alloy Wire Standard : IEC 62004 AT1 ,max. allowable continuous operating temperature 150 ℃.


Our company:

undefined

undefined


Test Equipment

undefined

Package and Delivery:

undefined

undefined


Honor

undefined

Product Categories : Overhead Cable

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Crazy Zhang Mr. Crazy Zhang
What can I do for you?
Contact Supplier