Huayuan Gaoke Cable Co.,Ltd.
TACSR/AS Conductor Cable,Aluminium Clad Steel Cores Cable,Thermal Aluminium Alloy Conductor Cable
Payment Type: | L/C,T/T,D/P,Paypal,Money Gram,Western Union |
---|---|
Incoterm: | FOB,CFR,CIF,FCA,CPT,CIP |
Min. Order: | 1000 Kilometer |
Model No.: TACSR
Brand: HUAYUAN YONGTONG
Type: Bare
Conductor Type: Stranded
Application: Overhead
Conductor Material: Aluminum
Insulation Material: Bare
Material Shape: Round Wire
Certification: ISO9001
Brand: HUAYUAN YONGTONG
Packaging: Drum
Productivity: 1000km/M
Transportation: Ocean,Land,Air
Place of Origin: Beijing,China
Supply Ability: 1000km/M
Certificate: CE,CCC,ISO
Port: Tianjin Port,Shanghai Port,Qingdao Port
Payment Type: L/C,T/T,D/P,Paypal,Money Gram,Western Union
Incoterm: FOB,CFR,CIF,FCA,CPT,CIP
Specification:
B.1 Technical Requirements |
|
|
B.1.1 Technical Characteristics and Requirements |
|
|
| Owner's Requirement | Offered |
a) Type | 410 mm2 TACSR | 410 mm2 TACSR |
b) Code Word | N/A | N/A |
c) Calculated total cross-sectional area, mm2 | 480.80 (approx.) | 480.80 (approx.) |
d) Outer Layers |
|
|
1.Material | Thermal Aluminum Zirconium Alloy (Al-Zir) | Thermal Aluminum Zirconium Alloy (Al-Zir) |
2.Calculated Cross-sectional Area, mm2 | 413.40 (approx.) | 413.40 (approx.) |
3.Stranding No./dia. No./mm | 26/4.5 | 26/4.5 |
4.Coefficient of Elongation (1°C) 1 |
| 23 × 10-6 |
e) Core |
|
|
1.Material | Al. Clad Steel (AS) | Al. Clad Steel (AS) |
2.Calculated Cross-sectional Area, (mm2)1 |
|
|
3.Stranding, No./Dia. No./mm | 7/3.5 | 7/3.5 |
4.Zinc coating (Class/g/m2) | N/A | N/A |
5.Coeff. Of Elongation (/°C) 1 |
| 13.0× 10-6 |
f) Conductor Overall Diameter, mm. | 28.50 (approx.) | 28.50 (approx.) |
g) Rated Tensile Strength (RTS), kg | Not less than 13,910 | ≥ 13910 |
h) Rated DC Resistance at 20°C, ohm/km 1 |
| ≤0.0694 |
i) Initial Modulus of Elasticity, (kg/mm2 )1 |
| 7700 |
j) Final Modulus of Elasticity, (kg/mm2) 1 |
| 7700 |
k) Percent Elongation at Rated Strength, % 1 |
| / |
I) Permanent Elongation due to 10 year creep at 20% RTS 1 |
| / |
m) Conductor Coeff. Of Linear Expansion (/°C) 1 |
| 18.9×10-6 |
B.1.2 Other Technical Requirements |
|
|
a)Conductor lay, (Right, Left) | Right | Right |
b)Length of Lay (Outer Layer) mm. 1 |
| 285--399(outside) |
c)Corrosion Inhibitor (Grease) Required? (Yes, No) | No | No |
d)Weight of Conductor (kg/km) 1 |
| 1587(approx) |
e)Length Per Reel, m. 1 |
| 2000 |
B.1.3 Cable Reel |
|
|
a) Material | Wooden2 | Wooden drums with steel reinforced |
b) Returnable, (Yes, No) | No | No |
c) If yes, return within no. of months after installation | N/A | N/A |
B.2 Tests and Experience Requirements |
|
|
B.2.1 Test Requirements |
|
|
| Owner's Requirement | Offered |
a) Stress-Strain Test and Report Required | Yes5 | yes |
b) Breaking Strength Test and Reports Required: | Yes6 | yes |
c)Factory Acceptance Tests (Routine Tests) to be witnessed by Owner's personnel. | No | No |
d) Required no. of Owner's personnel to witness test | N/A | N/A |
Conductor construction:
TACSR/AS 410 mm2
Construction | Nominal NO./Diameter(mm) | Nominal Diameter(mm) |
1--- Aluminum-Clad Steel Wire | 7 / 3.50 | 10.50 |
2--- Aluminum Alloy Wire | 26 / 4.50 | 28.50 |
Standard : IEC 61089 ; Aluminum-Clad Steel Wire standard : IEC 61232 20SA
Aluminum Alloy Wire Standard : IEC 62004 AT1 ,max. allowable continuous operating temperature 150 ℃.
Our company:
Test Equipment
Package and Delivery:
Honor
Product Categories : Overhead Cable