ABC CABLE Overhead Sheathed Aluminum Wire

    Payment Type: L/C,T/T,Paypal,Western Union
    Incoterm: FOB,CFR,CIF,FCA,CPT
    Min. Order: 1000 Meter
Basic Info

Model No.ABC

BrandHUAYUAN YONGTONG

TypeInsulated

Conductor TypeStranded

ApplicationHeating

Conductor MaterialCopper

Sheath MaterialPVC

Insulation MaterialPVC

Material ShapeRound Wire

Range of ApplicationCold-Resistant

CertificationISO9001

BrandHUAYUAN YONGTONG

Additional Info

PackagingDrum

Productivity1000km/M

TransportationOcean,Land,Air

Place of OriginBeijing,China

Supply Ability1000km/M

CertificateCE,CCC,ISO

HS Code8544601200

PortTianjin Port,Shanghai Port,Qingdao Port

Payment TypeL/C,T/T,Paypal,Western Union

IncotermFOB,CFR,CIF,FCA,CPT

Product Description

LV Aerial Bundled Conductor (ABC) Cables



Application

Aerial Bundle Cable (ABC Cable) is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system.

It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation, maintenance and operative cost.

Caledonian LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting.

This over-head cable provides reinforced insulation acc. IEC 61140 and fulfill therefore Class II acc. IEC 61140. It is not flame retardant. But this could be if requested change to a flame retardant cable.

Standard

Basic design to BS 7870 / TNB Specification(IEC 60502) / HD 626 S1 / NFC 33-209 / AS/NZS 3560-1 standards



What is the  overhead insulated cable??

Our overhead insulated cable have formed a system, such as single core, two-core, three-core and four-core. There are conductors of aluminum, copper or aluminum conductors steel-reinforced. 


Aluminum PVC Wire

Application

To be used at voltage of 600V pahse-to -pahse or less and at conductor temperatures not to exceed 750C for polyethylene insulated conductor or 900C for crossliked polyethlene (XLPE) insulated conductors. 


Alumium Building Wire


Cable's characteristics

1)  Rated voltage U:10kV

2) Installing temperature should not be below -200C.

 

3) admissible bending radius to cable:

4) Admissible bending radius to cable should be not less than 20(d+D)±5%mm.  

Where:D-real overall diameter of cable (mm). d-real diameter of conductor (mm)

Construction

Conductor Aluminium conductor, round stranded compressed (RM).
Insulation XPLE compound, UV-resistant.
Core Identification 1, 2 resp. 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm^2 and a minimum of 16 ribs for cores above 50 mm^2. In the case of five core bundles the surface of the protective core should be smooth.

 abc cable Dimensions


Nominal Area Number /Dia. Insulation Thickness Dcresistance PHASE NEUTRAL Rated Strength kn Delivery Lerngth
mm2 mm mm &Ω/km AAC AAAC km
1×16+16 7/1.70 1.3 1.7986 3.02 4.69 10
2×16+16 7/1.70 1.3 1.7986 3.02 4.69 7.5
3×16+16 7/1.70 1.3 1.7986 3.02 4.69 5
4×16 7/1.70 1.3 1.7986 3.02 4.69 5
1×25+25 7/2.10 1.3 1.1787 4.36 7.15 6.5
2×25+25 7/2.10 1.3 1.1787 4.36 7.15 5
3×25+25 7/2.10 1.3 1.1787 4.36 7.15 3.2
4×25 7/2.10 1.3 1.1787 4.36 7.15 3.2
1×35+35 7/2.50 1.3 0.8317 6.01 10.14 4.5
2×35+35 7/2.50 1.3 0.8317 6.01 10.14 3.5
3×35+35 7/2.50 1.3 0.8317 6.01 10.14 2.2
4×35 7/2.50 1.3 0.8317 6.01 10.14 2.2
1×50+50 7/3.0 1.5 0.5776 8.41 14.6 3
3×50+50 7/3.0 1.5 0.5776 8.41 14.6 1.3
1×70+70 19/2.10 1.5 0.4367 11.85 19.41 2.2
3×70+70 19/2.10 1.5 0.4367 11.85 19.41 0.8
3×95+95 19/2.50 1.6 0.3081 16.32 27.51 0.5

Electrical Properties

Rated Voltage 0.6/1kV
Test Voltage 4 Veff kV
Minimum Laying Temperature -20°C
Operating Temperature -40°C~ +90°C
Maximum Short-circuit Temperature 250°C
Maximum Conductor Temperature 80°C
Minimum Bending Radius 18×OD

Data sheet of abc cable

Number of Cores x Nominal Cross Section Overall Diameter Weight Maximum Conductor Resistance Minimum Breaking Load Current Rating
No.×mm^2 mm Kg/Km Ω/Km KN A
1x16 RM 8 74 1.91 2.5 72
1x25 RM 9 106 1.2 4 107
1x35 RM 10.5 138 0.868 5.5 132
1x50 RM 11.8 182 0.641 8 165
1x70 RM 13 252 0.443 10.7 205
1x95 RM 15.4 333 0.32 13.7 240
1x120 RM 17 408 0.253 18.6 290
1x150 RM 19 502 0.206 23.2 334
1x185 RM 21 611 0.164 28.7 389
1x240 RM 24 801 0.125 37.2 467
2x16 RM 15.6 147 1.91 2.5 72
2x25 RM 18 208 1.2 4 107
2x35 RM 20 277 0.868 5.5 132
2x50 RM 23.5 361 0.641 8 165
2x70 RM 25.4 505 0.443 10.7 205
2x95 RM 30.3 666 0.32 13.7 240
2x150 RM 38 1004 0.206 23.2 334
4x16 RM 18.8 286 1.91 2.5 72
4x25 RM 21.2 430 1.2 4 107
4x35 RM 24.1 553 0.868 5.5 132
4x50 RM 27.8 746 0.641 8 165
4x70 RM 31.8 1009 0.443 10.7 205
4x95 RM 37.8 1332 0.32 13.7 240
4x120 RM 54.4 1632 0.253 18.6 290


 

1KV XLPE Cable

AAC Aluminum Cable

Areial Cable



1 power cable certificte

2.Huayuan Gaoke Cabel Co.,Ltd

5producing6.contact4 Shipment