http://www.bjhygkcable.com
Accueil > Liste de Produits > Câblage d’immeuble > Fil de bâtiment de cuivre de basse tension de câble d'UL de câble de la puissance 600 volts XHHW 2

Fil de bâtiment de cuivre de basse tension de câble d'UL de câble de la puissance 600 volts XHHW 2

    Type de paiement: L/C,T/T,D/P,Paypal,Money Gram,Western Union
    Incoterm: FOB,CFR,CIF,FCA,CPT
    Quantité de commande minimum: 100 Meter
    Délai de livraison: 30 jours
Informations de base

Modèle: XHH2

Type: Insulated

Application: Heating

Conductor Material: Copper

Sheath Material: Crosslinking

Insulation Material: XLPE

Material Shape: Round Wire

Range of Application: LSOH

Certification: CCC

Brand: HUAYUAN YONGTONG

Additional Info

Détails d'emballage: BOBINE

productivité: 500KM/MONTH

marque: HUYUAN YONGTONG

transport: Ocean,Land,Air

Lieu d'origine: PÉKIN, CHINE

Capacité d'approvisionnement: 500KM/MONTH

Certificats : CE,CCC,ISO

Code SH: 8544601200

Hafen: Shanghai Port,Tianjin Port,Qingdao Port

Description du produit

Description du produit:

FIL DE CONSTRUCTION EN CUIVRE

CONSTRUCTION
 

 

 

 

 
STANDARD
 
ASTM,UL 44
 

 

 
VOLTAGE
 

 
600V
 

 

 

 
CONDUCTOR
 
soft annealed copper.#14-4/0AWGuses a compressed copper strand.
INSULATION
 
Cross-Linked Polyethylene (XLP) Insulation.
 
XHHW-2 copper conductors are annealed (soft) copper. Insulation is an
abrasion, moisture, and heat resistant thermoset cross-linked polyethylene (XLP). Conductor sizes 8
AWG and larger are marked sunlight resistant. Colors are available and may be subject to economic
order quantity.
APPLICATION
 

 

 

 

 

 
XHHW-2 conductors are primarily used in conduit,Cable Tray or other recognized raceways for service's, feeders, and branch circuit wiring,as specified in the National Electrical Code.XHHW-2 conductors may be used in wet or dry locations at temperatures not to exceed 90° C. Voltage rating for XHHW-2 conductors is 600volts.Suitable for use in Health Care Facilities per Section 517.160 of the National Electrical Code where a dielectric constant of less than 3.5 maybe specified. This cable is designed to be installed without the application of pulling lubricant.
CABLE  CONSTRUCTION

 

 

 

 

 

 

 

 
Conductor Insulation Max. DC 
Resistance at 20°C
Approx.weight
(AWG or kcmil) No of strands Thickness(mils)  Diameter(mils) Ohm/km 1000' (lbs)
14* 7 30 130 8.79 18
12* 1 30 141 5.41 24
10* 1 30 147 3.64 26
12* 7 30 162 9.10 37
10* 7 30 171 5.60 40
8 7 45 232 2.36 65
6 7 45 268 1.44 96
4 7 45 311 0.91 147
3 7 45 337 0.71 183
2 7 45 367 0.57 227
1 19 55 435 0.47 291
2/0 19 55 521 0.29 453
4/0 19 55 627 0.18 706

Power-600-Volts-XHHW-2-Cable-UL-Cable-Low-Voltage-Copper-Building-WirePower-600-Volts-XHHW-2-Cable-UL-Cable-Low-Voltage-Copper-Building-Wire (2)



1.Building Câble 2.Low Câble d'alimentation 3.0.6kv Câble 4.1kv Câble 5.Pvc flexible de contrôle